{"title":"Directional Control Valves","description":"\u003cp\u003eExplore our range of directional control valves for industrial and mobile hydraulic systems, including solenoid-operated, direct-operated and pilot-operated designs. Available in various CETOP and NG sizes, spool configurations, flow capacities and voltage options for reliable control of hydraulic actuators and fluid direction.\u003c\/p\u003e","products":[{"product_id":"ds3-s1-11n-d24k1-duplomatic-hydraulic-directional-control-valve-cetop-03-double-solenoid-100-l-min-350-bar-24v-dc","title":"DS3-S1\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S1\/11N-D24K1\u003c\/td\u003e\n\n      \u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500011\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSolenoid-operated directional control valve\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect operated\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03 \/ NG6)\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSubplate mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e31 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eMineral oil-based HL \/ HM fluids\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRecommended viscosity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e25 cSt\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e11\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S1\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S1\/11N-D24K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500011\u003c\/strong\u003e, is a direct-operated\n\u003cstrong\u003e4\/3 solenoid directional control valve\u003c\/strong\u003e designed for industrial\nhydraulic systems. The valve uses the standardized\n\u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting interface for easy\nintegration into hydraulic manifolds and subplates.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eS1 spool\u003c\/strong\u003e is operated by two solenoids and returns to the\ncenter position by spring centering. The valve supports a maximum flow rate of\n\u003cstrong\u003e100 l\/min\u003c\/strong\u003e and operating pressure up to\n\u003cstrong\u003e350 bar\u003c\/strong\u003e on ports P, A and B. Maximum allowable pressure on\nthe T return port for this DC version is \u003cstrong\u003e210 bar\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDS3-S1\/11N-D24K1\u003c\/strong\u003e is equipped with\n\u003cstrong\u003e24 V DC solenoids\u003c\/strong\u003e and a \u003cstrong\u003eK1 electrical connection\u003c\/strong\u003e\nfor EN 175301-803 (ex DIN 43650) connectors. Standard NBR seals are suitable\nfor mineral oil-based HL and HM hydraulic fluids.\n\u003c\/p\u003e\n\n\u003cp\u003e\nWith its compact CETOP 03 design, interchangeable solenoid coils and\nhigh operating pressure capability, the Duplomatic DS3 valve is suitable for\n\u003cstrong\u003ehydraulic power units, machine tools, presses, industrial machinery and automated hydraulic systems\u003c\/strong\u003e.\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S1\/11N-D24K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500011\u003c\/strong\u003e, for OEM, MRO and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":67829058404656,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-S1_11N-D24K1.jpg?v=1791305578"},{"product_id":"ds3-s1-11n-a110k1-duplomatic-hydraulic-directional-control-valve-cetop-03-double-solenoid-100-l-min-350-bar-110v-ac","title":"DS3-S1\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S1\/11N-A110K1\u003c\/td\u003e\n\n      \u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500101\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSolenoid-operated directional control valve\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect operated\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSubplate mounting\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption at 110 V \/ 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eMineral oil-based HL \/ HM fluids\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRecommended viscosity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e25 cSt\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S1\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S1\/11N-A110K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500101\u003c\/strong\u003e, is a direct-operated\n\u003cstrong\u003e4\/3 solenoid directional control valve\u003c\/strong\u003e designed for industrial\nhydraulic systems. The valve uses the standardized\n\u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting interface for integration\ninto hydraulic manifolds and subplates.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eS1 spool\u003c\/strong\u003e is operated by two AC solenoids and is\nspring-centered to the neutral position. The valve supports a maximum flow rate\nof \u003cstrong\u003e100 l\/min\u003c\/strong\u003e and a maximum operating pressure of\n\u003cstrong\u003e350 bar\u003c\/strong\u003e on ports P, A and B. Maximum allowable pressure on the\nT port for the AC version is \u003cstrong\u003e160 bar\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDS3-S1\/11N-A110K1\u003c\/strong\u003e is equipped with\n\u003cstrong\u003eA110 solenoids for 110 V AC \/ 50 Hz or 120 V AC \/ 60 Hz\u003c\/strong\u003e and\na \u003cstrong\u003eK1 electrical connection\u003c\/strong\u003e according to EN 175301-803\n(ex DIN 43650). Standard NBR seals are designed for mineral oil-based\nHL and HM hydraulic fluids.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe compact NG6 design, standardized mounting interface and interchangeable\nsolenoid coils make the Duplomatic DS3 suitable for\n\u003cstrong\u003ehydraulic power units, machine tools, presses, industrial automation and general machinery\u003c\/strong\u003e.\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S1\/11N-A110K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500101\u003c\/strong\u003e, for OEM, MRO and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":67829069807920,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s1-11n-a230k1-duplomatic-hydraulic-directional-control-valve-cetop-03-double-solenoid-100-l-min-350-bar-230v-ac","title":"DS3-S1\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S1\/11N-A230K1\u003c\/td\u003e\n\n      \u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500102\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSolenoid-operated directional control valve\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect operated\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSubplate mounting\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption at 230 V \/ 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eMineral oil-based HL \/ HM fluids\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRecommended viscosity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e25 cSt\u003c\/td\u003e\n\n      \u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S1\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S1\/11N-A230K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500102\u003c\/strong\u003e, is a direct-operated\n\u003cstrong\u003e4\/3 solenoid directional control valve\u003c\/strong\u003e designed for industrial\nhydraulic systems. The valve uses the standardized\n\u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting interface for integration\ninto hydraulic manifolds and subplates.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eS1 spool\u003c\/strong\u003e is actuated by two AC solenoids and returns to\nthe neutral position by spring centering. The valve supports a maximum flow rate\nof \u003cstrong\u003e100 l\/min\u003c\/strong\u003e and a maximum operating pressure of\n\u003cstrong\u003e350 bar\u003c\/strong\u003e on ports P, A and B. Maximum allowable pressure on\nthe T port for the AC version is \u003cstrong\u003e160 bar\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDS3-S1\/11N-A230K1\u003c\/strong\u003e is equipped with\n\u003cstrong\u003eA230 solenoids for 230 V AC \/ 50 Hz or 240 V AC \/ 60 Hz\u003c\/strong\u003e and\na \u003cstrong\u003eK1 electrical connection\u003c\/strong\u003e according to EN 175301-803\n(ex DIN 43650). Standard NBR seals are suitable for mineral oil-based\nHL and HM hydraulic fluids.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe compact NG6 design, standardized mounting interface and interchangeable\nsolenoid coils make the Duplomatic DS3 suitable for\n\u003cstrong\u003ehydraulic power units, machine tools, presses, industrial automation and general machinery\u003c\/strong\u003e.\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S1\/11N-A230K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500102\u003c\/strong\u003e, for OEM, MRO and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":67830065234224,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s1-11n-a230k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s1-spool-double-solenoid-with-spring-centering-230-v-ac-240-v-ac-max-flow-100-l-min-max-pressure-350-bar-k1-din-connection-and-nbr-seals-copy","title":"DS3-S2\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S2\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500014\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSolenoid-operated directional control valve\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e31 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S2\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S2\/11N-D24K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500014\u003c\/strong\u003e, is a direct-operated 4\/3 solenoid directional\ncontrol valve for industrial hydraulic systems.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe S2 spool is actuated by two solenoids and spring-centered to the neutral\nposition. The valve offers a maximum flow rate of \u003cstrong\u003e100 l\/min\u003c\/strong\u003e\nand maximum operating pressure of \u003cstrong\u003e350 bar\u003c\/strong\u003e on ports P, A and B.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThis version uses \u003cstrong\u003e24 V DC\u003c\/strong\u003e coils and a K1 electrical connection\naccording to EN 175301-803 (ex DIN 43650). The standardized ISO 4401-03 \/\nCETOP 03 mounting interface provides compatibility with NG6 manifolds and subplates.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S2\/11N-D24K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500014\u003c\/strong\u003e, for hydraulic power units,\nmachine tools, industrial automation, OEM and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68007972077872,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-S1_11N-D24K1.jpg?v=1791305578"},{"product_id":"ds3-s2-11n-a110k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s2-spool-double-solenoid-with-spring-centering-110-v-ac-120-v-ac-max-flow-100-l-min-max-pressure-350-bar-and-k1-din-connection","title":"DS3-S2\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S2\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500105\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSolenoid-operated directional control valve\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding at 110 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S2\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S2\/11N-A110K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500105\u003c\/strong\u003e, is a direct-operated 4\/3 directional control\nvalve with an S2 spool and double AC solenoid actuation.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe valve features spring centering, an ISO 4401-03 \/ CETOP 03 mounting\ninterface, maximum flow up to \u003cstrong\u003e100 l\/min\u003c\/strong\u003e and pressure up to\n\u003cstrong\u003e350 bar\u003c\/strong\u003e on ports P, A and B.\n\u003c\/p\u003e\n\n\u003cp\u003e\nA110 coils are suitable for \u003cstrong\u003e110 V AC \/ 50 Hz and 120 V AC \/ 60 Hz\u003c\/strong\u003e,\nwhile the K1 connection complies with EN 175301-803 (ex DIN 43650).\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S2\/11N-A110K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500105\u003c\/strong\u003e, for OEM equipment,\nhydraulic power units, machine tools and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68008000618800,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s2-11n-a230k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s2-spool-double-solenoid-with-spring-centering-230-v-ac-240-v-ac-max-flow-100-l-min-max-pressure-350-bar-and-k1-din-connection","title":"DS3-S2\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S2\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500106\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect-operated solenoid directional valve\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding at 230 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S2\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S2\/11N-A230K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500106\u003c\/strong\u003e, is a direct-operated 4\/3 directional valve\nwith an S2 spool, double solenoid actuation and spring centering.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe NG6 valve offers a maximum flow rate of \u003cstrong\u003e100 l\/min\u003c\/strong\u003e\nand maximum operating pressure up to \u003cstrong\u003e350 bar\u003c\/strong\u003e on ports P, A and B.\n\u003c\/p\u003e\n\n\u003cp\u003e\nA230 coils operate at \u003cstrong\u003e230 V AC \/ 50 Hz or 240 V AC \/ 60 Hz\u003c\/strong\u003e.\nThe K1 electrical interface is designed for EN 175301-803\n(ex DIN 43650) connectors.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S2\/11N-A230K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500106\u003c\/strong\u003e, for industrial hydraulic\nsystems, OEM, MRO and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68008003633456,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s3-11n-d24k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s3-spool-double-solenoid-with-spring-centering-24-v-dc-max-flow-100-l-min-max-pressure-350-bar-k1-din-connection-and-nbr-seals","title":"DS3-S3\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S3\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500017\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect-operated solenoid directional valve\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e31 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S3\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S3\/11N-D24K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500017\u003c\/strong\u003e, is a direct-operated NG6 4\/3 directional\ncontrol valve with an S3 spool.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe valve uses two solenoids with spring centering and supports flow rates\nup to \u003cstrong\u003e100 l\/min\u003c\/strong\u003e and operating pressure up to\n\u003cstrong\u003e350 bar\u003c\/strong\u003e on P, A and B ports.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThis version uses \u003cstrong\u003e24 V DC\u003c\/strong\u003e coils, NBR seals and a K1\nEN 175301-803 electrical connection.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S3\/11N-D24K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500017\u003c\/strong\u003e, for machine tools,\nhydraulic power units, automation and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68008006353200,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s3-11n-a110k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s3-spool-double-solenoid-with-spring-centering-110-v-ac-120-v-ac-max-flow-100-l-min-and-max-pressure-350-bar","title":"DS3-S3\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S3\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500109\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding at 110 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S3\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S3\/11N-A110K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500109\u003c\/strong\u003e, is a direct-operated 4\/3 NG6 directional\ncontrol valve with an S3 spool.\n\u003c\/p\u003e\n\n\u003cp\u003e\nDouble solenoid actuation and spring centering provide reliable directional\ncontrol in industrial hydraulic circuits. Maximum pressure is\n\u003cstrong\u003e350 bar\u003c\/strong\u003e and maximum series flow is \u003cstrong\u003e100 l\/min\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe A110 version operates at \u003cstrong\u003e110 V AC \/ 50 Hz or 120 V AC \/ 60 Hz\u003c\/strong\u003e\nand uses a K1 EN 175301-803 connection.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S3\/11N-A110K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500109\u003c\/strong\u003e, for OEM, MRO and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68008009466160,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s3-11n-a230k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s3-spool-double-solenoid-with-spring-centering-230-v-ac-240-v-ac-max-flow-100-l-min-and-max-pressure-350-bar","title":"DS3-S3\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S3\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500110\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding at 230 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR for mineral oils\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S3\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S3\/11N-A230K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500110\u003c\/strong\u003e, is a direct-operated 4\/3 directional valve\nwith an S3 spool and standardized NG6 mounting interface.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe valve uses two AC solenoids with spring centering and supports operating\npressure up to \u003cstrong\u003e350 bar\u003c\/strong\u003e and maximum series flow up to\n\u003cstrong\u003e100 l\/min\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe A230 coils operate at \u003cstrong\u003e230 V AC \/ 50 Hz or 240 V AC \/ 60 Hz\u003c\/strong\u003e,\nwith K1 electrical connection according to EN 175301-803.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S3\/11N-A230K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500110\u003c\/strong\u003e, for industrial machinery,\nhydraulic power units and replacement projects.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68008069988656,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s3-11n-d24k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s3-spool-double-solenoid-with-spring-centering-24-v-dc-max-flow-100-l-min-max-pressure-350-bar-k1-din-connection-and-nbr-seals-copy","title":"DS3-S4\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S4\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500020\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS4\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect-operated solenoid directional valve\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e31 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S4\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S4\/11N-D24K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500020\u003c\/strong\u003e, is a direct-operated 4\/3 solenoid directional\ncontrol valve with an S4 spool.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe valve features double solenoid actuation, spring centering and a\nstandardized ISO 4401-03 \/ CETOP 03 mounting interface. Maximum pressure\nis \u003cstrong\u003e350 bar\u003c\/strong\u003e and maximum DS3 series flow is \u003cstrong\u003e100 l\/min\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThis configuration uses \u003cstrong\u003e24 V DC\u003c\/strong\u003e coils, K1 electrical\nconnection and standard NBR seals for mineral oil-based hydraulic fluids.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S4\/11N-D24K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500020\u003c\/strong\u003e, for industrial hydraulic\nsystems, OEM equipment and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68008070545712,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s4-11n-a110k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s4-spool-double-solenoid-with-spring-centering-110-v-ac-120-v-ac-max-flow-100-l-min-and-max-pressure-350-bar","title":"DS3-S4\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S4\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500113\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS4\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding at 110 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S4\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S4\/11N-A110K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500113\u003c\/strong\u003e, is a direct-operated NG6 4\/3 directional\ncontrol valve with an S4 spool.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe valve uses double AC solenoids and spring centering and is designed for\nISO 4401-03 \/ CETOP 03 subplate mounting. Maximum pressure is\n\u003cstrong\u003e350 bar\u003c\/strong\u003e and maximum DS3 series flow is \u003cstrong\u003e100 l\/min\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe A110 coils operate with \u003cstrong\u003e110 V AC \/ 50 Hz or 120 V AC \/ 60 Hz\u003c\/strong\u003e\nand use the standard K1 electrical connection.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-S4\/11N-A110K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500113\u003c\/strong\u003e, for industrial machinery,\nhydraulic power units and replacement projects.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68008075624752,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-s4-11n-a230k1-duplomatic-4-3-solenoid-operated-directional-control-valve-cetop-03-ng6-s4-spool-double-solenoid-with-spring-centering-230-v-ac-240-v-ac-max-flow-100-l-min-max-pressure-350-bar-and-k1-din-connection","title":"DS3-S4\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-S4\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eS4\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect-operated solenoid directional valve\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 3-position\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool centering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eSpring centered\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding at 230 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-S4\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-S4\/11N-A230K1\u003c\/strong\u003e is a direct-operated\n4\/3 solenoid directional control valve with an S4 spool and standardized\nNG6 mounting interface.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe valve uses two AC solenoids with spring centering and supports maximum\npressure up to \u003cstrong\u003e350 bar\u003c\/strong\u003e on P, A and B ports and maximum\nDS3 series flow up to \u003cstrong\u003e100 l\/min\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe A230 configuration operates with \u003cstrong\u003e230 V AC \/ 50 Hz or\n240 V AC \/ 60 Hz\u003c\/strong\u003e and uses a K1 connection according to\nEN 175301-803 (ex DIN 43650).\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDuplomatic DS3-S4\/11N-A230K1\u003c\/strong\u003e\nfor hydraulic power units, machine tools, industrial automation,\nOEM and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68008076443952,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-rk-11n-d24k1-duplomatic-4-2-solenoid-operated-directional-control-valve-cetop-03-ng6-rk-spool-with-mechanical-detent-double-solenoid-24-v-dc-max-flow-100-l-min-max-pressure-350-bar-k1-din-connection-and-nbr-seals","title":"DS3-RK\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-RK\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500065\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDirect-operated solenoid directional valve\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eRK\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool retention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eMechanical detent\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eLongitudinal axis horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e31 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-RK\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-RK\/11N-D24K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500065\u003c\/strong\u003e, is a direct-operated 4\/2 solenoid directional\ncontrol valve with mechanical spool retention.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eRK spool\u003c\/strong\u003e is actuated by two solenoids and mechanically\nretained in the selected position, allowing the valve to maintain its switching\nstate after the electrical signal is removed.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe valve uses \u003cstrong\u003e24 V DC\u003c\/strong\u003e coils, an ISO 4401-03 \/ CETOP 03\nmounting interface and supports pressures up to \u003cstrong\u003e350 bar\u003c\/strong\u003e\nand DS3 series flow up to \u003cstrong\u003e100 l\/min\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-RK\/11N-D24K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500065\u003c\/strong\u003e, for hydraulic power units,\nindustrial machinery, machine tools and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68035461349680,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-rk-11n-a110k1-duplomatic-4-2-solenoid-operated-directional-control-valve-cetop-03-ng6-rk-spool-with-mechanical-detent-double-solenoid-110-v-ac-120-v-ac-max-flow-100-l-min-and-max-pressure-350-bar","title":"DS3-RK\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-RK\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuplomatic article code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e3411500152\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eRK\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool retention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eMechanical detent\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eLongitudinal axis horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding at 110 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-RK\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-RK\/11N-A110K1\u003c\/strong\u003e, article code\n\u003cstrong\u003e3411500152\u003c\/strong\u003e, is a direct-operated 4\/2 NG6 directional\nvalve with mechanical detent.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe RK spool is actuated by two AC solenoids and remains mechanically\nretained in the selected operating position until the opposite solenoid is energized.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe A110 version operates with \u003cstrong\u003e110 V AC \/ 50 Hz or 120 V AC \/ 60 Hz\u003c\/strong\u003e,\nuses the standardized CETOP 03 mounting interface and supports pressure up to\n\u003cstrong\u003e350 bar\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDS3-RK\/11N-A110K1\u003c\/strong\u003e,\nDuplomatic article \u003cstrong\u003e3411500152\u003c\/strong\u003e, for industrial hydraulic\nsystems, OEM equipment and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68035475079472,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-rk-11n-a230k1-duplomatic-4-2-solenoid-operated-directional-control-valve-cetop-03-ng6-rk-spool-with-mechanical-detent-double-solenoid-230-v-ac-240-v-ac-max-flow-100-l-min-and-max-pressure-350-bar","title":"DS3-RK\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:40px;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDS3-RK\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%; padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eRK\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eDouble solenoid\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool retention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eMechanical detent\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03 (CETOP 03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding at 230 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eLongitudinal axis horizontal\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 24px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px 10px 0; border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 0; border-bottom:1px solid #e1e1e1;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\n\u003ch2\u003eDuplomatic DS3-RK\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDuplomatic DS3-RK\/11N-A230K1\u003c\/strong\u003e is a direct-operated\n4\/2 directional control valve with an RK mechanically retained spool.\n\u003c\/p\u003e\n\n\u003cp\u003e\nTwo AC solenoids provide switching between the two operating positions,\nwhile the mechanical detent retains the selected spool position.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe valve operates with \u003cstrong\u003e230 V AC \/ 50 Hz or 240 V AC \/ 60 Hz\u003c\/strong\u003e,\nuses an ISO 4401-03 \/ CETOP 03 mounting interface and supports pressure\nup to \u003cstrong\u003e350 bar\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIMPEX CONNECT supplies \u003cstrong\u003eDuplomatic DS3-RK\/11N-A230K1\u003c\/strong\u003e\nfor industrial hydraulic systems, machinery and replacement applications.\n\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68035483959600,"sku":null,"price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/komponentai-pramonei-3309-332-120557.jpg?v=1790080122"},{"product_id":"ds3-ta-11n-d24k1-duplomatic-directional-control-valve","title":"DS3-TA\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003cp\u003eDuplomatic DS3-TA\/11N-D24K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 24 V DC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e31 W (1.29 A nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA\/11N-D24K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e24 V DC\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, with a maximum T-port pressure of \u003cstrong\u003e210 bar\u003c\/strong\u003e. For this DC TA\/TB configuration, the standard 4-port operating diagram specifies flow up to \u003cstrong\u003e100 l\/min\u003c\/strong\u003e (catalogue section 6.1, DC curve 7). Three-port operation, a blocked working port or operation without flow in one working line requires checking the separate limits in section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA\/11N-D24K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68078440055088,"sku":"DS3-TA\/11N-D24K1","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA_11N-D24K1_f78631ae-4cce-44d8-9e33-08d6161e51e1.jpg?v=1792071029"},{"product_id":"ds3-ta-11n-a110k1-duplomatic-directional-control-valve","title":"DS3-TA\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003cp\u003eDuplomatic DS3-TA\/11N-A110K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 110 V AC \/ 120 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding (110 V, 50 Hz); 185 VA \/ 42 VA (120 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA\/11N-A110K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, with a maximum T-port pressure of \u003cstrong\u003e160 bar\u003c\/strong\u003e. For this AC TA\/TB configuration, the standard 4-port operating diagram specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e (catalogue section 6.1, AC curve 1). Three-port operation, a blocked working port or operation without flow in one working line requires checking the separate limits in section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA\/11N-A110K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68078440120624,"sku":"DS3-TA\/11N-A110K1","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA_11N-A110K1_f0b1dc14-329f-4f6f-809a-813df52ed41d.jpg?v=1792071029"},{"product_id":"ds3-ta-11n-a230k1-duplomatic-directional-control-valve","title":"DS3-TA\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003cp\u003eDuplomatic DS3-TA\/11N-A230K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 230 V AC \/ 240 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding (230 V, 50 Hz); 190 VA \/ 43 VA (240 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA\/11N-A230K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, with a maximum T-port pressure of \u003cstrong\u003e160 bar\u003c\/strong\u003e. For this AC TA\/TB configuration, the standard 4-port operating diagram specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e (catalogue section 6.1, AC curve 1). Three-port operation, a blocked working port or operation without flow in one working line requires checking the separate limits in section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA\/11N-A230K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68078448312624,"sku":"DS3-TA\/11N-A230K1","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA_11N-A230K1_237d91cc-b582-477d-9868-33635e5adaf0.jpg?v=1792071030"},{"product_id":"ds3-tb-11n-d24k1-duplomatic-directional-control-valve","title":"DS3-TB\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003cp\u003eDuplomatic DS3-TB\/11N-D24K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side B and spring return. It features an NG6 \/ CETOP 03 mounting interface, 24 V DC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TB\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e31 W (1.29 A nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TB\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TB\/11N-D24K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TB spool uses one solenoid on \u003cstrong\u003eside B\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e24 V DC\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, with a maximum T-port pressure of \u003cstrong\u003e210 bar\u003c\/strong\u003e. For this DC TA\/TB configuration, the standard 4-port operating diagram specifies flow up to \u003cstrong\u003e100 l\/min\u003c\/strong\u003e (catalogue section 6.1, DC curve 7). Three-port operation, a blocked working port or operation without flow in one working line requires checking the separate limits in section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TB\/11N-D24K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68078448378160,"sku":"DS3-TB\/11N-D24K1","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TB_11N-D24K1_41867dc1-6fa8-44e9-befd-fc743f3e4cfb.jpg?v=1792071031"},{"product_id":"ds3-tb-11n-a110k1-duplomatic-directional-control-valve","title":"DS3-TB\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003cp\u003eDuplomatic DS3-TB\/11N-A110K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side B and spring return. It features an NG6 \/ CETOP 03 mounting interface, 110 V AC \/ 120 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TB\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding (110 V, 50 Hz); 185 VA \/ 42 VA (120 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TB\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TB\/11N-A110K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TB spool uses one solenoid on \u003cstrong\u003eside B\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, with a maximum T-port pressure of \u003cstrong\u003e160 bar\u003c\/strong\u003e. For this AC TA\/TB configuration, the standard 4-port operating diagram specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e (catalogue section 6.1, AC curve 1). Three-port operation, a blocked working port or operation without flow in one working line requires checking the separate limits in section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TB\/11N-A110K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68078448410928,"sku":"DS3-TB\/11N-A110K1","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TB_11N-A110K1_f9aef539-b22b-4a54-8314-6e24c298da7c.jpg?v=1792071031"},{"product_id":"ds3-tb-11n-a230k1-duplomatic-directional-control-valve","title":"DS3-TB\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003cp\u003eDuplomatic DS3-TB\/11N-A230K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side B and spring return. It features an NG6 \/ CETOP 03 mounting interface, 230 V AC \/ 240 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TB\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding (230 V, 50 Hz); 190 VA \/ 43 VA (240 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TB\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TB\/11N-A230K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TB spool uses one solenoid on \u003cstrong\u003eside B\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, with a maximum T-port pressure of \u003cstrong\u003e160 bar\u003c\/strong\u003e. For this AC TA\/TB configuration, the standard 4-port operating diagram specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e (catalogue section 6.1, AC curve 1). Three-port operation, a blocked working port or operation without flow in one working line requires checking the separate limits in section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TB\/11N-A230K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68078448476464,"sku":"DS3-TB\/11N-A230K1","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TB_11N-A230K1_d8a5a1cc-dd76-451e-ae54-b4b17c694283.jpg?v=1792071032"},{"product_id":"ds3-ta02-11n-d24k1-duplomatic-directional-control-valve","title":"DS3-TA02\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003cp\u003eDuplomatic DS3-TA02\/11N-D24K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 24 V DC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA02\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e31 W (1.29 A nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA02\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA02\/11N-D24K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA02 spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e24 V DC\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e210 bar\u003c\/strong\u003e. The TA02 spool has an open crossover condition during switching. In standard 4-port operation, DC curve 8 permits flow up to \u003cstrong\u003e100 l\/min at 200 bar\u003c\/strong\u003e; the permissible flow decreases at higher pressures. Do not combine the maximum flow and maximum pressure as a single operating point. See catalogue section 6.1. Three-port operation, a blocked working port or operation without flow in one working line requires checking section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA02\/11N-D24K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858562864,"sku":"DS3-TA02\/11N-D24K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA02_11N-D24K1_463fbf72-6022-443c-85e0-dc1e2696a58d.jpg?v=1792073079"},{"product_id":"ds3-ta02-11n-a110k1-duplomatic-directional-control-valve","title":"DS3-TA02\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003cp\u003eDuplomatic DS3-TA02\/11N-A110K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 110 V AC \/ 120 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA02\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding (110 V, 50 Hz); 185 VA \/ 42 VA (120 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA02\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA02\/11N-A110K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA02 spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e160 bar\u003c\/strong\u003e. The TA02 spool has an open crossover condition during switching. In standard 4-port operation, AC curve 1 specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e. See catalogue section 6.1. Three-port operation, a blocked working port or operation without flow in one working line requires checking section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA02\/11N-A110K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858628400,"sku":"DS3-TA02\/11N-A110K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA02_11N-A110K1_2b3e9c19-5e81-4223-8884-722e4e35cfb4.jpg?v=1792073080"},{"product_id":"ds3-ta02-11n-a230k1-duplomatic-directional-control-valve","title":"DS3-TA02\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003cp\u003eDuplomatic DS3-TA02\/11N-A230K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 230 V AC \/ 240 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA02\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding (230 V, 50 Hz); 190 VA \/ 43 VA (240 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA02\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA02\/11N-A230K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA02 spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e160 bar\u003c\/strong\u003e. The TA02 spool has an open crossover condition during switching. In standard 4-port operation, AC curve 1 specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e. See catalogue section 6.1. Three-port operation, a blocked working port or operation without flow in one working line requires checking section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA02\/11N-A230K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858661168,"sku":"DS3-TA02\/11N-A230K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA02_11N-A230K1_e7b3a3d8-01ab-4b19-984b-86927a1f3d14.jpg?v=1792073081"},{"product_id":"ds3-tb02-11n-d24k1-duplomatic-directional-control-valve","title":"DS3-TB02\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003cp\u003eDuplomatic DS3-TB02\/11N-D24K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side B and spring return. It features an NG6 \/ CETOP 03 mounting interface, 24 V DC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TB02\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTB02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e31 W (1.29 A nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TB02\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TB02\/11N-D24K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TB02 spool uses one solenoid on \u003cstrong\u003eside B\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e24 V DC\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e210 bar\u003c\/strong\u003e. The TB02 spool has an open crossover condition during switching. In standard 4-port operation, DC curve 8 permits flow up to \u003cstrong\u003e100 l\/min at 200 bar\u003c\/strong\u003e; the permissible flow decreases at higher pressures. Do not combine the maximum flow and maximum pressure as a single operating point. See catalogue section 6.1. Three-port operation, a blocked working port or operation without flow in one working line requires checking section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TB02\/11N-D24K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858726704,"sku":"DS3-TB02\/11N-D24K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TB02_11N-D24K1_f7c87777-fda9-489f-bb1c-dd7bd3ef7da4.jpg?v=1792073082"},{"product_id":"ds3-tb02-11n-a110k1-duplomatic-directional-control-valve","title":"DS3-TB02\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003cp\u003eDuplomatic DS3-TB02\/11N-A110K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side B and spring return. It features an NG6 \/ CETOP 03 mounting interface, 110 V AC \/ 120 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TB02\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTB02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding (110 V, 50 Hz); 185 VA \/ 42 VA (120 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TB02\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TB02\/11N-A110K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TB02 spool uses one solenoid on \u003cstrong\u003eside B\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e160 bar\u003c\/strong\u003e. The TB02 spool has an open crossover condition during switching. In standard 4-port operation, AC curve 1 specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e. See catalogue section 6.1. Three-port operation, a blocked working port or operation without flow in one working line requires checking section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TB02\/11N-A110K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858792240,"sku":"DS3-TB02\/11N-A110K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TB02_11N-A110K1_379f4819-993b-417e-9090-840f95c5da2a.jpg?v=1792073083"},{"product_id":"ds3-tb02-11n-a230k1-duplomatic-directional-control-valve","title":"DS3-TB02\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003cp\u003eDuplomatic DS3-TB02\/11N-A230K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side B and spring return. It features an NG6 \/ CETOP 03 mounting interface, 230 V AC \/ 240 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TB02\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTB02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding (230 V, 50 Hz); 190 VA \/ 43 VA (240 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TB02\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TB02\/11N-A230K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TB02 spool uses one solenoid on \u003cstrong\u003eside B\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e160 bar\u003c\/strong\u003e. The TB02 spool has an open crossover condition during switching. In standard 4-port operation, AC curve 1 specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e. See catalogue section 6.1. Three-port operation, a blocked working port or operation without flow in one working line requires checking section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TB02\/11N-A230K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858825008,"sku":"DS3-TB02\/11N-A230K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TB02_11N-A230K1_9df10441-b336-4cbb-9d09-ce3e57d8fb05.jpg?v=1792073084"},{"product_id":"ds3-ta23-11n-d24k1-duplomatic-directional-control-valve","title":"DS3-TA23\/11N-D24K1 - Duplomatic directional valve · 24V DC","description":"\u003cp\u003eDuplomatic DS3-TA23\/11N-D24K1 is a direct-operated 3\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 24 V DC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA23\/11N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e3-way, 2-position (port B blocked)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e60 l\/min; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e31 W (1.29 A nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA23\/11N-D24K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA23\/11N-D24K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA23 spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e24 V DC\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e210 bar\u003c\/strong\u003e. The TA23 spool provides a \u003cstrong\u003e3\/2 function with port B blocked\u003c\/strong\u003e. Its operating limit is up to \u003cstrong\u003e60 l\/min\u003c\/strong\u003e according to catalogue section 6.1, DC curve 2. Verify the operating point against the manufacturer's diagram.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA23\/11N-D24K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858890544,"sku":"DS3-TA23\/11N-D24K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA23_11N-D24K1_fdb565f5-c066-4aeb-9465-4f54bbba1fa0.jpg?v=1792073085"},{"product_id":"ds3-ta23-11n-a110k1-duplomatic-directional-control-valve","title":"DS3-TA23\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003cp\u003eDuplomatic DS3-TA23\/11N-A110K1 is a direct-operated 3\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 110 V AC \/ 120 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA23\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e3-way, 2-position (port B blocked)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e60 l\/min; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding (110 V, 50 Hz); 185 VA \/ 42 VA (120 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA23\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA23\/11N-A110K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA23 spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e160 bar\u003c\/strong\u003e. The TA23 spool provides a \u003cstrong\u003e3\/2 function with port B blocked\u003c\/strong\u003e. Its operating limit is up to \u003cstrong\u003e60 l\/min\u003c\/strong\u003e according to catalogue section 6.1, AC curve 2. Verify the operating point against the manufacturer's diagram.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA23\/11N-A110K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858956080,"sku":"DS3-TA23\/11N-A110K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA23_11N-A110K1_64e4975e-c609-48a3-84c5-78240942fd4f.jpg?v=1792073086"},{"product_id":"ds3-ta23-11n-a230k1-duplomatic-directional-control-valve","title":"DS3-TA23\/11N-A230K1 - Duplomatic directional valve · 230V AC","description":"\u003cp\u003eDuplomatic DS3-TA23\/11N-A230K1 is a direct-operated 3\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 230 V AC \/ 240 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA23\/11N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e3-way, 2-position (port B blocked)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e60 l\/min; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e213 VA inrush \/ 48 VA holding (230 V, 50 Hz); 190 VA \/ 43 VA (240 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA23\/11N-A230K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA23\/11N-A230K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA23 spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e160 bar\u003c\/strong\u003e. The TA23 spool provides a \u003cstrong\u003e3\/2 function with port B blocked\u003c\/strong\u003e. Its operating limit is up to \u003cstrong\u003e60 l\/min\u003c\/strong\u003e according to catalogue section 6.1, AC curve 2. Verify the operating point against the manufacturer's diagram.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA23\/11N-A230K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080859021616,"sku":"DS3-TA23\/11N-A230K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA23_11N-A230K1_1e692884-ba04-47d5-811b-a2d32d711fab.jpg?v=1792073087"},{"product_id":"ds5-s1-14n-d12k1","title":"DS5-S1\/14N-D12K1 - Duplomatic NG10 4\/3 closed centre directional valve, 12 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S1\/14N-D12K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 closed centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP, A, B and T blocked\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S1\/14N-D12K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S1\/14N-D12K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS1\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 closed centre\u003c\/strong\u003e. With the solenoids de-energized: P, A, B and T blocked. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 12 V DC. Series 14 identifies the DC version. The valve has 2 DC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S1\/14N-D12K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182271033648,"sku":"DS5-S1\/14N-D12K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-dc-cad.jpg?v=1793027729"},{"product_id":"ds5-s1-14n-d24k1","title":"DS5-S1\/14N-D24K1 - Duplomatic NG10 4\/3 closed centre directional valve, 24 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S1\/14N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 closed centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP, A, B and T blocked\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S1\/14N-D24K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S1\/14N-D24K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS1\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 closed centre\u003c\/strong\u003e. With the solenoids de-energized: P, A, B and T blocked. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 24 V DC. Series 14 identifies the DC version. The valve has 2 DC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S1\/14N-D24K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182271131952,"sku":"DS5-S1\/14N-D24K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-dc-cad.jpg?v=1793027729"},{"product_id":"ds5-s1-12n-a110k1","title":"DS5-S1\/12N-A110K1 - Duplomatic NG10 4\/3 closed centre directional valve, 110 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S1\/12N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 closed centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP, A, B and T blocked\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S1\/12N-A110K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S1\/12N-A110K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS1\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 closed centre\u003c\/strong\u003e. With the solenoids de-energized: P, A, B and T blocked. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 2 AC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S1\/12N-A110K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182271164720,"sku":"DS5-S1\/12N-A110K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-ac-cad.jpg?v=1793027740"},{"product_id":"ds5-s1-12n-a230k1","title":"DS5-S1\/12N-A230K1 - Duplomatic NG10 4\/3 closed centre directional valve, 230 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S1\/12N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 closed centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP, A, B and T blocked\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S1\/12N-A230K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S1\/12N-A230K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS1\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 closed centre\u003c\/strong\u003e. With the solenoids de-energized: P, A, B and T blocked. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 2 AC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S1\/12N-A230K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182271230256,"sku":"DS5-S1\/12N-A230K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-ac-cad.jpg?v=1793027740"},{"product_id":"ds5-s2-14n-d12k1","title":"DS5-S2\/14N-D12K1 - Duplomatic NG10 4\/3 open centre directional valve, 12 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S2\/14N-D12K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 open centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP, A, B and T interconnected\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S2\/14N-D12K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S2\/14N-D12K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS2\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 open centre\u003c\/strong\u003e. With the solenoids de-energized: P, A, B and T interconnected. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 12 V DC. Series 14 identifies the DC version. The valve has 2 DC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S2\/14N-D12K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182271394096,"sku":"DS5-S2\/14N-D12K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-dc-cad.jpg?v=1793027729"},{"product_id":"ds5-s2-14n-d24k1","title":"DS5-S2\/14N-D24K1 - Duplomatic NG10 4\/3 open centre directional valve, 24 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S2\/14N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 open centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP, A, B and T interconnected\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S2\/14N-D24K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S2\/14N-D24K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS2\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 open centre\u003c\/strong\u003e. With the solenoids de-energized: P, A, B and T interconnected. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 24 V DC. Series 14 identifies the DC version. The valve has 2 DC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S2\/14N-D24K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182271557936,"sku":"DS5-S2\/14N-D24K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-dc-cad.jpg?v=1793027729"},{"product_id":"ds5-s2-12n-a110k1","title":"DS5-S2\/12N-A110K1 - Duplomatic NG10 4\/3 open centre directional valve, 110 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S2\/12N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 open centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP, A, B and T interconnected\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S2\/12N-A110K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S2\/12N-A110K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS2\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 open centre\u003c\/strong\u003e. With the solenoids de-energized: P, A, B and T interconnected. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 2 AC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S2\/12N-A110K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182271623472,"sku":"DS5-S2\/12N-A110K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-ac-cad.jpg?v=1793027740"},{"product_id":"ds5-s2-12n-a230k1","title":"DS5-S2\/12N-A230K1 - Duplomatic NG10 4\/3 open centre directional valve, 230 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S2\/12N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 open centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP, A, B and T interconnected\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S2\/12N-A230K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S2\/12N-A230K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS2\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 open centre\u003c\/strong\u003e. With the solenoids de-energized: P, A, B and T interconnected. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 2 AC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S2\/12N-A230K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182271951152,"sku":"DS5-S2\/12N-A230K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-ac-cad.jpg?v=1793027740"},{"product_id":"ds5-s3-14n-d12k1","title":"DS5-S3\/14N-D12K1 - Duplomatic NG10 4\/3 float centre directional valve, 12 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S3\/14N-D12K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 float centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP blocked; A and B connected to T\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S3\/14N-D12K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S3\/14N-D12K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS3\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 float centre\u003c\/strong\u003e. With the solenoids de-energized: P blocked; A and B connected to T. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 12 V DC. Series 14 identifies the DC version. The valve has 2 DC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S3\/14N-D12K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182272180528,"sku":"DS5-S3\/14N-D12K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-dc-cad.jpg?v=1793027729"},{"product_id":"ds5-s3-14n-d24k1","title":"DS5-S3\/14N-D24K1 - Duplomatic NG10 4\/3 float centre directional valve, 24 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S3\/14N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 float centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP blocked; A and B connected to T\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S3\/14N-D24K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S3\/14N-D24K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS3\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 float centre\u003c\/strong\u003e. With the solenoids de-energized: P blocked; A and B connected to T. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 24 V DC. Series 14 identifies the DC version. The valve has 2 DC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S3\/14N-D24K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182272278832,"sku":"DS5-S3\/14N-D24K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-dc-cad.jpg?v=1793027729"},{"product_id":"ds5-s3-12n-a110k1","title":"DS5-S3\/12N-A110K1 - Duplomatic NG10 4\/3 float centre directional valve, 110 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S3\/12N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 float centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP blocked; A and B connected to T\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S3\/12N-A110K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S3\/12N-A110K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS3\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 float centre\u003c\/strong\u003e. With the solenoids de-energized: P blocked; A and B connected to T. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 2 AC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S3\/12N-A110K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182272475440,"sku":"DS5-S3\/12N-A110K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-ac-cad.jpg?v=1793027740"},{"product_id":"ds5-s3-12n-a230k1","title":"DS5-S3\/12N-A230K1 - Duplomatic NG10 4\/3 float centre directional valve, 230 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S3\/12N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 float centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP blocked; A and B connected to T\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S3\/12N-A230K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S3\/12N-A230K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS3\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 float centre\u003c\/strong\u003e. With the solenoids de-energized: P blocked; A and B connected to T. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 2 AC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S3\/12N-A230K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182272672048,"sku":"DS5-S3\/12N-A230K1","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-ac-cad.jpg?v=1793027740"},{"product_id":"ds5-s4-14n-d12k1","title":"DS5-S4\/14N-D12K1 - Duplomatic NG10 4\/3 tandem centre directional valve, 12 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S4\/14N-D12K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS4\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 tandem centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP connected to T; A and B blocked\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S4\/14N-D12K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S4\/14N-D12K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS4\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 tandem centre\u003c\/strong\u003e. With the solenoids de-energized: P connected to T; A and B blocked. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 12 V DC. Series 14 identifies the DC version. The valve has 2 DC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S4\/14N-D12K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182272770352,"sku":"DS5-S4\/14N-D12K1","price":240.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-dc-cad.jpg?v=1793027729"},{"product_id":"ds5-s4-14n-d24k1","title":"DS5-S4\/14N-D24K1 - Duplomatic NG10 4\/3 tandem centre directional valve, 24 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S4\/14N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS4\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 tandem centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP connected to T; A and B blocked\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S4\/14N-D24K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S4\/14N-D24K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS4\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 tandem centre\u003c\/strong\u003e. With the solenoids de-energized: P connected to T; A and B blocked. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 24 V DC. Series 14 identifies the DC version. The valve has 2 DC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S4\/14N-D24K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182272835888,"sku":"DS5-S4\/14N-D24K1","price":240.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-dc-cad.jpg?v=1793027729"},{"product_id":"ds5-s4-12n-a110k1","title":"DS5-S4\/12N-A110K1 - Duplomatic NG10 4\/3 tandem centre directional valve, 110 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S4\/12N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS4\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 tandem centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP connected to T; A and B blocked\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S4\/12N-A110K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S4\/12N-A110K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS4\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 tandem centre\u003c\/strong\u003e. With the solenoids de-energized: P connected to T; A and B blocked. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 2 AC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S4\/12N-A110K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182272901424,"sku":"DS5-S4\/12N-A110K1","price":240.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-ac-cad.jpg?v=1793027740"},{"product_id":"ds5-s4-12n-a230k1","title":"DS5-S4\/12N-A230K1 - Duplomatic NG10 4\/3 tandem centre directional valve, 230 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-S4\/12N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eS4\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/3 tandem centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP connected to T; A and B blocked\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTwo solenoids; spring centering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-S4\/12N-A230K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-S4\/12N-A230K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eS4\u003c\/strong\u003e provides \u003cstrong\u003e4\/3 tandem centre\u003c\/strong\u003e. With the solenoids de-energized: P connected to T; A and B blocked. Two solenoids; spring centering.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 2 AC solenoids and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external two-solenoid AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-S4\/12N-A230K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182272934192,"sku":"DS5-S4\/12N-A230K1","price":240.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-dual-ac-cad.jpg?v=1793027740"},{"product_id":"ds5-ta-14n-d12k1","title":"DS5-TA\/14N-D12K1 - Duplomatic NG10 4\/2 spring return directional valve, 12 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-TA\/14N-D12K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTA\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/2 spring return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSpring-return working position; see TA hydraulic symbol\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eOne solenoid on side A; spring return between two working positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-TA\/14N-D12K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-TA\/14N-D12K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eTA\u003c\/strong\u003e provides \u003cstrong\u003e4\/2 spring return\u003c\/strong\u003e. With the solenoid de-energized: Spring-return working position; see TA hydraulic symbol. One solenoid on side A; spring return between two working positions.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 12 V DC. Series 14 identifies the DC version. The valve has 1 DC solenoid and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external single-solenoid, side A DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-TA\/14N-D12K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182273032496,"sku":"DS5-TA\/14N-D12K1","price":160.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-single-a-dc-cad.jpg?v=1793027734"},{"product_id":"ds5-ta-14n-d24k1","title":"DS5-TA\/14N-D24K1 - Duplomatic NG10 4\/2 spring return directional valve, 24 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-TA\/14N-D24K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTA\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/2 spring return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSpring-return working position; see TA hydraulic symbol\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eOne solenoid on side A; spring return between two working positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-TA\/14N-D24K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-TA\/14N-D24K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eTA\u003c\/strong\u003e provides \u003cstrong\u003e4\/2 spring return\u003c\/strong\u003e. With the solenoid de-energized: Spring-return working position; see TA hydraulic symbol. One solenoid on side A; spring return between two working positions.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard DC version, the T-port limit is \u003cstrong\u003e210 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 24 V DC. Series 14 identifies the DC version. The valve has 1 DC solenoid and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external single-solenoid, side A DC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-TA\/14N-D24K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182273098032,"sku":"DS5-TA\/14N-D24K1","price":160.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-single-a-dc-cad.jpg?v=1793027734"},{"product_id":"ds5-ta-12n-a110k1","title":"DS5-TA\/12N-A110K1 - Duplomatic NG10 4\/2 spring return directional valve, 110 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-TA\/12N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTA\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/2 spring return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSpring-return working position; see TA hydraulic symbol\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eOne solenoid on side A; spring return between two working positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-TA\/12N-A110K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-TA\/12N-A110K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eTA\u003c\/strong\u003e provides \u003cstrong\u003e4\/2 spring return\u003c\/strong\u003e. With the solenoid de-energized: Spring-return working position; see TA hydraulic symbol. One solenoid on side A; spring return between two working positions.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 1 AC solenoid and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external single-solenoid, side A AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-TA\/12N-A110K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182273163568,"sku":"DS5-TA\/12N-A110K1","price":160.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-single-a-ac-cad.jpg?v=1793027745"},{"product_id":"ds5-ta-12n-a230k1","title":"DS5-TA\/12N-A230K1 - Duplomatic NG10 4\/2 spring return directional valve, 230 V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDS5-TA\/12N-A230K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect acting directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTA\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4\/2 spring return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of solenoids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNumber of positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSpring-return working position; see TA hydraulic symbol\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eOne solenoid on side A; spring return between two working positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e140 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 l\/min; subject to spool operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNot supplied; order separately\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard, integrated in the solenoid tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10% of nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M6 × 40, ISO 4762; torque 8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DS5-TA\/12N-A230K1 NG10 directional control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDS5-TA\/12N-A230K1\u003c\/strong\u003e is a direct acting solenoid operated directional control valve for NG10 \/ CETOP 05 subplate mounting. Spool \u003cstrong\u003eTA\u003c\/strong\u003e provides \u003cstrong\u003e4\/2 spring return\u003c\/strong\u003e. With the solenoid de-energized: Spring-return working position; see TA hydraulic symbol. One solenoid on side A; spring return between two working positions.\u003c\/p\u003e\u003cp\u003eThe maximum pressure at P, A and B is 320 bar. For this standard AC version, the T-port limit is \u003cstrong\u003e140 bar\u003c\/strong\u003e and catalogue maximum flow is \u003cstrong\u003e120 l\/min\u003c\/strong\u003e. Actual permissible flow depends on spool, pressure and circuit arrangement; check the operating-limit curves in the catalogue. This product is the standard version without the optional Y external drain.\u003c\/p\u003e\u003cp\u003eSupply: 230 V AC \/ 50 Hz; 240 V AC \/ 60 Hz. Series 12 identifies the AC version. The valve has 1 AC solenoid and a standard integrated manual override. K1 connectors are not included. NBR seals suit HL\/HM mineral hydraulic oil. The CAD view and DWG correspond to the external single-solenoid, side A AC construction; the selected spool function is defined by the ordering code and hydraulic symbol.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDS5-TA\/12N-A230K1\u003c\/strong\u003e for industrial hydraulic systems. Match the ISO mounting interface, spool function, return condition, voltage and T-port pressure when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68182273524016,"sku":"DS5-TA\/12N-A230K1","price":160.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-ds5-single-a-ac-cad.jpg?v=1793027745"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/collections\/Duplomatic_Directional_valves_300dpi.png?v=1790093020","url":"https:\/\/impex-connect.com\/collections\/directional-control-valves.oembed?page=4","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}