{"title":"Flow Control Valves","description":"\u003cp\u003eHydraulic flow control valves for adjusting cylinder and hydraulic motor speed. Choose by valve function, flow rate, working pressure and mounting size. IMPEX CONNECT supplies Duplomatic components, including QTM3 replacements for MERS. Technical selection, prices and delivery times are available on request.\u003c\/p\u003e","products":[{"product_id":"duplomatic-qtm3-d-10n-s","title":"QTM3-D\/10N\/S - Duplomatic NG6 throttle check valve, A and B, meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-D\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-D\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMeter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHexagon socket screw (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-D\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-D\/10N\/S\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe D configuration restricts flow leaving the actuator through A and B. The built-in check valves allow free reverse flow. Flow is set with a 6 mm hexagon socket adjustment screw. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-D\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-D\/10N\/S\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-D\/50\u003c\/strong\u003e. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. Optional \/W7 zinc-nickel treatment is available to order. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-D\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151429267760,"sku":"QTM3-D\/10N\/S","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-d-10n-s-cad.jpg?v=1792657608"},{"product_id":"duplomatic-qtm3-d-10n-ck3","title":"QTM3-D\/10N\/CK3 - Duplomatic NG6 throttle check valve, A and B, meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-D\/10N\/CK3\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-D\/M\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMeter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePush-adjust-lock knob (CK3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-D\/10N\/CK3 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-D\/10N\/CK3\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe D configuration restricts flow leaving the actuator through A and B. The built-in check valves allow free reverse flow. The CK3 knob engages when pressed and turned, and disengages when released to prevent accidental adjustment. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-D\/M\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-D\/10N\/CK3\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-D\/M\/50\u003c\/strong\u003e with M \/ SICBLOC adjustment. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. CK3 is the current push-adjust-lock adjustment; the catalogue does not offer \/W7 with CK3. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-D\/10N\/CK3\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151429300528,"sku":"QTM3-D\/10N\/CK3","price":85.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-d-10n-ck3-cad.jpg?v=1792657613"},{"product_id":"duplomatic-qtm3-rd-10n-s","title":"QTM3-RD\/10N\/S - Duplomatic NG6 throttle check valve, A and B, meter-in, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-RD\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-RD\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMeter-in\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHexagon socket screw (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-RD\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-RD\/10N\/S\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-in\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe RD configuration restricts the flow entering the actuator through A and B. The check valves allow free flow in the reverse direction. Flow is set with a 6 mm hexagon socket adjustment screw. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-RD\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-RD\/10N\/S\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-RD\/50\u003c\/strong\u003e. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. Optional \/W7 zinc-nickel treatment is available to order. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-RD\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151429366064,"sku":"QTM3-RD\/10N\/S","price":80.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-rd-10n-s-cad.jpg?v=1792657619"},{"product_id":"duplomatic-qtm3-rd-10n-ck3","title":"QTM3-RD\/10N\/CK3 - Duplomatic NG6 throttle check valve, A and B, meter-in, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-RD\/10N\/CK3\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-RD\/M\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMeter-in\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePush-adjust-lock knob (CK3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-RD\/10N\/CK3 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-RD\/10N\/CK3\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-in\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe RD configuration restricts the flow entering the actuator through A and B. The check valves allow free flow in the reverse direction. The CK3 knob engages when pressed and turned, and disengages when released to prevent accidental adjustment. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-RD\/M\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-RD\/10N\/CK3\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-RD\/M\/50\u003c\/strong\u003e with M \/ SICBLOC adjustment. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. CK3 is the current push-adjust-lock adjustment; the catalogue does not offer \/W7 with CK3. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-RD\/10N\/CK3\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151429398832,"sku":"QTM3-RD\/10N\/CK3","price":95.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-rd-10n-ck3-cad.jpg?v=1792657624"},{"product_id":"duplomatic-qtm3-sa-10n-s","title":"QTM3-SA\/10N\/S - Duplomatic NG6 throttle check valve, A, meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-SA\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-SA\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMeter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHexagon socket screw (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-SA\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-SA\/10N\/S\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in line \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe SA configuration restricts flow leaving the actuator through A. The built-in check valve allows free reverse flow. Flow is set with a 6 mm hexagon socket adjustment screw. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-SA\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-SA\/10N\/S\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-SA\/50\u003c\/strong\u003e. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. Optional \/W7 zinc-nickel treatment is available to order. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-SA\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151429529904,"sku":"QTM3-SA\/10N\/S","price":65.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-sa-10n-s-cad.jpg?v=1792657649"},{"product_id":"duplomatic-qtm3-sa-10n-ck3","title":"QTM3-SA\/10N\/CK3 - Duplomatic NG6 throttle check valve, A, meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-SA\/10N\/CK3\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-SA\/M\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMeter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePush-adjust-lock knob (CK3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-SA\/10N\/CK3 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-SA\/10N\/CK3\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in line \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe SA configuration restricts flow leaving the actuator through A. The built-in check valve allows free reverse flow. The CK3 knob engages when pressed and turned, and disengages when released to prevent accidental adjustment. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-SA\/M\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-SA\/10N\/CK3\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-SA\/M\/50\u003c\/strong\u003e with M \/ SICBLOC adjustment. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. CK3 is the current push-adjust-lock adjustment; the catalogue does not offer \/W7 with CK3. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-SA\/10N\/CK3\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151429562672,"sku":"QTM3-SA\/10N\/CK3","price":80.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-sa-10n-ck3-cad.jpg?v=1792657655"},{"product_id":"duplomatic-qtm3-sb-10n-s","title":"QTM3-SB\/10N\/S - Duplomatic NG6 throttle check valve, B, meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-SB\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-SB\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMeter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHexagon socket screw (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-SB\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-SB\/10N\/S\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in line \u003cstrong\u003eB\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe SB configuration restricts flow leaving the actuator through B. The built-in check valve allows free reverse flow. Flow is set with a 6 mm hexagon socket adjustment screw. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-SB\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-SB\/10N\/S\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-SB\/50\u003c\/strong\u003e. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. Optional \/W7 zinc-nickel treatment is available to order. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-SB\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151429628208,"sku":"QTM3-SB\/10N\/S","price":65.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-sb-10n-s-cad.jpg?v=1792657658"},{"product_id":"duplomatic-qtm3-sb-10n-ck3","title":"QTM3-SB\/10N\/CK3 - Duplomatic NG6 throttle check valve, B, meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-SB\/10N\/CK3\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-SB\/M\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMeter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePush-adjust-lock knob (CK3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-SB\/10N\/CK3 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-SB\/10N\/CK3\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in line \u003cstrong\u003eB\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe SB configuration restricts flow leaving the actuator through B. The built-in check valve allows free reverse flow. The CK3 knob engages when pressed and turned, and disengages when released to prevent accidental adjustment. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-SB\/M\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-SB\/10N\/CK3\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-SB\/M\/50\u003c\/strong\u003e with M \/ SICBLOC adjustment. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. CK3 is the current push-adjust-lock adjustment; the catalogue does not offer \/W7 with CK3. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-SB\/10N\/CK3\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151430218032,"sku":"QTM3-SB\/10N\/CK3","price":80.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-sb-10n-ck3-cad.jpg?v=1792657662"},{"product_id":"duplomatic-qtm3-gd-10n-s","title":"QTM3-GD\/10N\/S - Duplomatic NG6 throttle check valve, A and B, reversible meter-in \/ meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-GD\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-GD\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eReversible meter-in \/ meter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHexagon socket screw (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-GD\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-GD\/10N\/S\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003ereversible meter-in \/ meter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe G configuration is reversible: meter-in or meter-out operation depends on the orientation of the valve on the supplied sealing subplate. The valve body has no O-ring seats; the sealing subplate is included. Flow is set with a 6 mm hexagon socket adjustment screw. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-GD\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-GD\/10N\/S\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-GD\/50\u003c\/strong\u003e. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. Optional \/W7 zinc-nickel treatment is available to order. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-GD\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151430283568,"sku":"QTM3-GD\/10N\/S","price":80.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-gd-10n-s-cad.jpg?v=1792657696"},{"product_id":"duplomatic-qtm3-gd-10n-ck3","title":"QTM3-GD\/10N\/CK3 - Duplomatic NG6 throttle check valve, A and B, reversible meter-in \/ meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-GD\/10N\/CK3\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-GD\/M\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eReversible meter-in \/ meter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePush-adjust-lock knob (CK3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-GD\/10N\/CK3 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-GD\/10N\/CK3\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003ereversible meter-in \/ meter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe G configuration is reversible: meter-in or meter-out operation depends on the orientation of the valve on the supplied sealing subplate. The valve body has no O-ring seats; the sealing subplate is included. The CK3 knob engages when pressed and turned, and disengages when released to prevent accidental adjustment. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-GD\/M\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-GD\/10N\/CK3\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-GD\/M\/50\u003c\/strong\u003e with M \/ SICBLOC adjustment. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. CK3 is the current push-adjust-lock adjustment; the catalogue does not offer \/W7 with CK3. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-GD\/10N\/CK3\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151430414640,"sku":"QTM3-GD\/10N\/CK3","price":95.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-gd-10n-ck3-cad.jpg?v=1792657701"},{"product_id":"duplomatic-qtm3-gsa-10n-s","title":"QTM3-GSA\/10N\/S - Duplomatic NG6 throttle check valve, A, reversible meter-in \/ meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-GSA\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-GSA\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eReversible meter-in \/ meter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHexagon socket screw (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-GSA\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-GSA\/10N\/S\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in line \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003ereversible meter-in \/ meter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe G configuration is reversible: meter-in or meter-out operation depends on the orientation of the valve on the supplied sealing subplate. The valve body has no O-ring seats; the sealing subplate is included. Flow is set with a 6 mm hexagon socket adjustment screw. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-GSA\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-GSA\/10N\/S\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-GSA\/50\u003c\/strong\u003e. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. Optional \/W7 zinc-nickel treatment is available to order. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-GSA\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151430447408,"sku":"QTM3-GSA\/10N\/S","price":80.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-gsa-10n-s-cad.jpg?v=1792657706"},{"product_id":"duplomatic-qtm3-gsa-10n-ck3","title":"QTM3-GSA\/10N\/CK3 - Duplomatic NG6 throttle check valve, A, reversible meter-in \/ meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-GSA\/10N\/CK3\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-GSA\/M\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eReversible meter-in \/ meter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePush-adjust-lock knob (CK3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-GSA\/10N\/CK3 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-GSA\/10N\/CK3\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in line \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003ereversible meter-in \/ meter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe G configuration is reversible: meter-in or meter-out operation depends on the orientation of the valve on the supplied sealing subplate. The valve body has no O-ring seats; the sealing subplate is included. The CK3 knob engages when pressed and turned, and disengages when released to prevent accidental adjustment. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-GSA\/M\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-GSA\/10N\/CK3\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-GSA\/M\/50\u003c\/strong\u003e with M \/ SICBLOC adjustment. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. CK3 is the current push-adjust-lock adjustment; the catalogue does not offer \/W7 with CK3. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-GSA\/10N\/CK3\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151430480176,"sku":"QTM3-GSA\/10N\/CK3","price":95.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-gsa-10n-ck3-cad.jpg?v=1792657712"},{"product_id":"duplomatic-qtm3-gsb-10n-s","title":"QTM3-GSB\/10N\/S - Duplomatic NG6 throttle check valve, B, reversible meter-in \/ meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-GSB\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-GSB\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eReversible meter-in \/ meter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHexagon socket screw (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-GSB\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-GSB\/10N\/S\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in line \u003cstrong\u003eB\u003c\/strong\u003e using \u003cstrong\u003ereversible meter-in \/ meter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe G configuration is reversible: meter-in or meter-out operation depends on the orientation of the valve on the supplied sealing subplate. The valve body has no O-ring seats; the sealing subplate is included. Flow is set with a 6 mm hexagon socket adjustment screw. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-GSB\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-GSB\/10N\/S\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-GSB\/50\u003c\/strong\u003e. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. Optional \/W7 zinc-nickel treatment is available to order. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-GSB\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151430512944,"sku":"QTM3-GSB\/10N\/S","price":80.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-gsb-10n-s-cad.jpg?v=1792657739"},{"product_id":"duplomatic-qtm3-gsb-10n-ck3","title":"QTM3-GSB\/10N\/CK3 - Duplomatic NG6 throttle check valve, B, reversible meter-in \/ meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3-GSB\/10N\/CK3\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eQTM3 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePrevious MERS code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMERS-GSB\/M\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eReversible meter-in \/ meter-out\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePush-adjust-lock knob (CK3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4401-03 \/ CETOP 03 \/ NG6\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eModular sandwich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum controlled-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum free-line flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e75 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMinimum controlled flow\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e≤ 0.060 l\/min at Δp 10 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM3-GSB\/10N\/CK3 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM3-GSB\/10N\/CK3\u003c\/strong\u003e is a non-compensated hydraulic flow restrictor with a check valve for free reverse flow. It controls flow in line \u003cstrong\u003eB\u003c\/strong\u003e using \u003cstrong\u003ereversible meter-in \/ meter-out\u003c\/strong\u003e operation. The ISO 4401-03 \/ CETOP 03 \/ NG6 sandwich interface allows installation in compact hydraulic valve stacks on power units, machine tools and industrial machinery.\u003c\/p\u003e\u003cp\u003eThe G configuration is reversible: meter-in or meter-out operation depends on the orientation of the valve on the supplied sealing subplate. The valve body has no O-ring seats; the sealing subplate is included. The CK3 knob engages when pressed and turned, and disengages when released to prevent accidental adjustment. Turn anticlockwise to increase the flow.\u003c\/p\u003e\u003ch3\u003eReplacement for MERS-GSB\/M\/50\u003c\/h3\u003e\u003cp\u003eThe QTM3 series succeeds MERS. For the corresponding hydraulic function and adjustment, \u003cstrong\u003eQTM3-GSB\/10N\/CK3\u003c\/strong\u003e is the current selection for the previous \u003cstrong\u003eMERS-GSB\/M\/50\u003c\/strong\u003e with M \/ SICBLOC adjustment. Confirm the full old code, circuit symbol, seals and installation clearances when replacing an existing valve; the overall dimensions are not identical in every version. CK3 is the current push-adjust-lock adjustment; the catalogue does not offer \/W7 with CK3. FPM seals (V) are a separate execution for compatible special fluids.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM3-GSB\/10N\/CK3\u003c\/strong\u003e for industrial hydraulic systems. Prices exclude VAT. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151430545712,"sku":"QTM3-GSB\/10N\/CK3","price":95.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm3-gsb-10n-ck3-cad.jpg?v=1792657744"},{"product_id":"duplomatic-qtm5-d-10n-s","title":"QTM5-D\/10N\/S - Duplomatic NG10 throttle check valve, A and B, meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-D\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA and B\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHexagon socket screw, 5 mm (S)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-D\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-D\/10N\/S\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eD\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses a socket hex adjustment screw (5 mm) and a locking nut (17 mm spanner). Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-D\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151741350192,"sku":"QTM5-D\/10N\/S","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-d-10n-s-cad.jpg?v=1792663290"},{"product_id":"duplomatic-qtm5-d-10n-k1","title":"QTM5-D\/10N\/K1 - Duplomatic NG10 throttle check valve, A and B, meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-D\/10N\/K1\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA and B\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment knob (K1)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-D\/10N\/K1 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-D\/10N\/K1\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eD\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses the optional K1 adjustment knob. Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-D\/10N\/K1\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151741415728,"sku":"QTM5-D\/10N\/K1","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-d-10n-k1-cad.jpg?v=1792663301"},{"product_id":"duplomatic-qtm5-rd-10n-s","title":"QTM5-RD\/10N\/S - Duplomatic NG10 throttle check valve, A and B, meter-in, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-RD\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA and B\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHexagon socket screw, 5 mm (S)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-RD\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-RD\/10N\/S\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eRD\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-in\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses a socket hex adjustment screw (5 mm) and a locking nut (17 mm spanner). Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-RD\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151741514032,"sku":"QTM5-RD\/10N\/S","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-rd-10n-s-cad.jpg?v=1792663311"},{"product_id":"duplomatic-qtm5-rd-10n-k1","title":"QTM5-RD\/10N\/K1 - Duplomatic NG10 throttle check valve, A and B, meter-in, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-RD\/10N\/K1\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA and B\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment knob (K1)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-RD\/10N\/K1 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-RD\/10N\/K1\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eRD\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-in\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses the optional K1 adjustment knob. Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-RD\/10N\/K1\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151741579568,"sku":"QTM5-RD\/10N\/K1","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-rd-10n-k1-cad.jpg?v=1792663316"},{"product_id":"duplomatic-qtm5-sa-10n-s","title":"QTM5-SA\/10N\/S - Duplomatic NG10 throttle check valve, A, meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-SA\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHexagon socket screw, 5 mm (S)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-SA\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-SA\/10N\/S\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eSA\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses a socket hex adjustment screw (5 mm) and a locking nut (17 mm spanner). Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-SA\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151741677872,"sku":"QTM5-SA\/10N\/S","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-sa-10n-s-cad.jpg?v=1792663321"},{"product_id":"duplomatic-qtm5-sa-10n-k1","title":"QTM5-SA\/10N\/K1 - Duplomatic NG10 throttle check valve, A, meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-SA\/10N\/K1\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment knob (K1)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-SA\/10N\/K1 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-SA\/10N\/K1\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eSA\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses the optional K1 adjustment knob. Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-SA\/10N\/K1\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151741710640,"sku":"QTM5-SA\/10N\/K1","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-sa-10n-k1-cad.jpg?v=1792663325"},{"product_id":"duplomatic-qtm5-sb-10n-s","title":"QTM5-SB\/10N\/S - Duplomatic NG10 throttle check valve, B, meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-SB\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eB\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHexagon socket screw, 5 mm (S)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-SB\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-SB\/10N\/S\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eSB\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eB\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses a socket hex adjustment screw (5 mm) and a locking nut (17 mm spanner). Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-SB\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151742562608,"sku":"QTM5-SB\/10N\/S","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-sb-10n-s-cad.jpg?v=1792663330"},{"product_id":"duplomatic-qtm5-sb-10n-k1","title":"QTM5-SB\/10N\/K1 - Duplomatic NG10 throttle check valve, B, meter-out, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-SB\/10N\/K1\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eB\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment knob (K1)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-SB\/10N\/K1 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-SB\/10N\/K1\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eSB\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eB\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses the optional K1 adjustment knob. Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-SB\/10N\/K1\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151742628144,"sku":"QTM5-SB\/10N\/K1","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-sb-10n-k1-cad.jpg?v=1792663335"},{"product_id":"duplomatic-qtm5-rsa-10n-s","title":"QTM5-RSA\/10N\/S - Duplomatic NG10 throttle check valve, A, meter-in, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-RSA\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHexagon socket screw, 5 mm (S)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-RSA\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-RSA\/10N\/S\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eRSA\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003emeter-in\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses a socket hex adjustment screw (5 mm) and a locking nut (17 mm spanner). Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-RSA\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151742693680,"sku":"QTM5-RSA\/10N\/S","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-rsa-10n-s-cad.jpg?v=1792663341"},{"product_id":"duplomatic-qtm5-rsa-10n-k1","title":"QTM5-RSA\/10N\/K1 - Duplomatic NG10 throttle check valve, A, meter-in, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-RSA\/10N\/K1\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment knob (K1)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-RSA\/10N\/K1 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-RSA\/10N\/K1\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eRSA\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003emeter-in\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses the optional K1 adjustment knob. Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-RSA\/10N\/K1\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151742759216,"sku":"QTM5-RSA\/10N\/K1","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-rsa-10n-k1-cad.jpg?v=1792663346"},{"product_id":"duplomatic-qtm5-rsb-10n-s","title":"QTM5-RSB\/10N\/S - Duplomatic NG10 throttle check valve, B, meter-in, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-RSB\/10N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eB\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHexagon socket screw, 5 mm (S)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-RSB\/10N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-RSB\/10N\/S\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eRSB\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eB\u003c\/strong\u003e using \u003cstrong\u003emeter-in\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses a socket hex adjustment screw (5 mm) and a locking nut (17 mm spanner). Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-RSB\/10N\/S\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151742791984,"sku":"QTM5-RSB\/10N\/S","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-rsb-10n-s-cad.jpg?v=1792663350"},{"product_id":"duplomatic-qtm5-rsb-10n-k1","title":"QTM5-RSB\/10N\/K1 - Duplomatic NG10 throttle check valve, B, meter-in, knob adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5-RSB\/10N\/K1\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM5 - 10\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eB\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-05-04-0-05 \/ CETOP 05\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment knob (K1)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.5 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM5-RSB\/10N\/K1 modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM5-RSB\/10N\/K1\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eRSB\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eB\u003c\/strong\u003e using \u003cstrong\u003emeter-in\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-05 \/ CETOP 05 \/ NG10 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses the optional K1 adjustment knob. Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e120 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM5-RSB\/10N\/K1\u003c\/strong\u003e for industrial hydraulic systems. Price, availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68151742857520,"sku":"QTM5-RSB\/10N\/K1","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm5-rsb-10n-k1-cad.jpg?v=1792663357"},{"product_id":"duplomatic-qtm7-d-20n-s","title":"QTM7-D\/20N\/S - Duplomatic NG16 throttle check valve, A and B, meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM7-D\/20N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM7 - 20\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA and B\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-07-07-0-05 \/ CETOP 07\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e300 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHexagon socket screw, 8 mm (S)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.7 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-25 to +80 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-25 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM7-D\/20N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM7-D\/20N\/S\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eD\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA and B\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-07 \/ CETOP 07 \/ NG16 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses a socket hex adjustment screw (8 mm) and a locking nut (24 mm spanner). Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e300 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM7-D\/20N\/S\u003c\/strong\u003e for industrial hydraulic systems. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68153226461488,"sku":"QTM7-D\/20N\/S","price":710.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm7-d-20n-s-cad.jpg?v=1792679101"},{"product_id":"duplomatic-qtm7-sa-20n-s","title":"QTM7-SA\/20N\/S - Duplomatic NG16 throttle check valve, A, meter-out, screw adjustment","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM7-SA\/20N\/S\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eQTM7 - 20\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNon-compensated throttle check valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eControlled lines\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eA\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFlow control\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMeter-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMounting interface\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4401-07-07-0-05 \/ CETOP 07\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNG16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMaximum flow rate\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e300 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAdjustment\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHexagon socket screw, 8 mm (S)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eSeals\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eNBR (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCheck valve cracking pressure\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e0.7 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e6.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-25 to +80 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e-25 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eViscosity range\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e10-400 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eRecommended viscosity\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003e25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eHydraulic fluid\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #dce4e9;padding:10px 12px;text-align:left\"\u003eMineral oil HL \/ HM, ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QTM7-SA\/20N\/S modular flow restrictor valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQTM7-SA\/20N\/S\u003c\/strong\u003e is a non-compensated throttle check valve for hydraulic cylinder and motor speed control. The \u003cstrong\u003eSA\u003c\/strong\u003e configuration restricts flow in lines \u003cstrong\u003eA\u003c\/strong\u003e using \u003cstrong\u003emeter-out\u003c\/strong\u003e control and allows free reverse flow through the built-in check valve. The modular ISO 4401-07 \/ CETOP 07 \/ NG16 interface fits compatible sandwich valve stacks without external connecting pipes.\u003c\/p\u003e\u003cp\u003eThis version uses a socket hex adjustment screw (8 mm) and a locking nut (24 mm spanner). Turn anticlockwise to increase flow. Catalogue limits are \u003cstrong\u003e350 bar\u003c\/strong\u003e maximum operating pressure and \u003cstrong\u003e300 l\/min\u003c\/strong\u003e maximum flow. Flow depends on pressure differential and adjustment; this valve does not provide pressure or temperature compensation.\u003c\/p\u003e\u003cp\u003eNBR seals (N) are specified for mineral hydraulic oils HL or HM. FPM seals (V) for suitable special fluids are a separate execution. Check the circuit function, mounting interface and installation dimensions before selecting a replacement. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQTM7-SA\/20N\/S\u003c\/strong\u003e for industrial hydraulic systems. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68153226559792,"sku":"QTM7-SA\/20N\/S","price":685.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qtm7-sa-20n-s-cad.jpg?v=1792679107"},{"product_id":"rs2-30","title":"RS2\/30 - Duplomatic 1\/4\" BSP bidirectional throttle valve, 15 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS2\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\/4\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e15 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1\/4\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e49 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e78 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS2\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS2\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for in-line installation with 1\/4\" BSP ports. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e15 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e400 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThe threaded body is supplied for direct installation in the hydraulic line. Body dimensions are C = 49 mm, D = 20 mm and E max = 78 mm; adjustment knob diameter is 50 mm. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190547116336,"sku":"RS2\/30","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs2-30-cad.jpg?v=1793105149"},{"product_id":"rs2-i-30","title":"RS2-I\/30 - Duplomatic M20x1.5 cartridge bidirectional throttle valve, 15 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS2-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 (1\/4\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e15 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M20x1.5; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e49.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e26.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2043 \/ 2043\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-513; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS2-I\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS2-I\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for screw-in mounting in a hydraulic manifold block. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e15 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThis is the \u003cstrong\u003e-I cartridge version\u003c\/strong\u003e, with a M20x1.5 mounting thread. The 1\/4\" designation indicates equivalent RS nominal size, not a BSP connection on the cartridge. Match the complete cavity drawing, not only the thread. The type 400-513 bonded seal is excluded from supply. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190547149104,"sku":"RS2-I\/30","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs2-i-30-cad.jpg?v=1793105153"},{"product_id":"rs3-30","title":"RS3\/30 - Duplomatic 3\/8\" BSP bidirectional throttle valve, 30 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS3\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\/8\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 3\/8\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e59 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e93 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS3\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS3\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for in-line installation with 3\/8\" BSP ports. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e30 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e400 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThe threaded body is supplied for direct installation in the hydraulic line. Body dimensions are C = 59 mm, D = 25 mm and E max = 93 mm; adjustment knob diameter is 70 mm. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190547444016,"sku":"RS3\/30","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs3-30-cad.jpg?v=1793105157"},{"product_id":"rs3-i-30","title":"RS3-I\/30 - Duplomatic M20x1.5 cartridge bidirectional throttle valve, 30 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS3-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3 (3\/8\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M20x1.5; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e70 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e57.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2050 \/ 2050\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-513; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS3-I\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS3-I\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for screw-in mounting in a hydraulic manifold block. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e30 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThis is the \u003cstrong\u003e-I cartridge version\u003c\/strong\u003e, with a M20x1.5 mounting thread. The 3\/8\" designation indicates equivalent RS nominal size, not a BSP connection on the cartridge. Match the complete cavity drawing, not only the thread. The type 400-513 bonded seal is excluded from supply. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190547476784,"sku":"RS3-I\/30","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs3-i-30-cad.jpg?v=1793105162"},{"product_id":"rs4-30","title":"RS4\/30 - Duplomatic 1\/2\" BSP bidirectional throttle valve, 50 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS4\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\/2\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1\/2\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e68 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e107 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS4\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS4\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for in-line installation with 1\/2\" BSP ports. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e50 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e400 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThe threaded body is supplied for direct installation in the hydraulic line. Body dimensions are C = 68 mm, D = 30 mm and E max = 107 mm; adjustment knob diameter is 80 mm. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190547706160,"sku":"RS4\/30","price":80.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs4-30-cad.jpg?v=1793105166"},{"product_id":"rs4-i-30","title":"RS4-I\/30 - Duplomatic M27x2 cartridge bidirectional throttle valve, 50 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS4-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 (1\/2\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M27x2; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e66.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e40 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2062 \/ 2062\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-520; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS4-I\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS4-I\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for screw-in mounting in a hydraulic manifold block. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e50 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThis is the \u003cstrong\u003e-I cartridge version\u003c\/strong\u003e, with a M27x2 mounting thread. The 1\/2\" designation indicates equivalent RS nominal size, not a BSP connection on the cartridge. Match the complete cavity drawing, not only the thread. The type 400-520 bonded seal is excluded from supply. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190547738928,"sku":"RS4-I\/30","price":80.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs4-i-30-cad.jpg?v=1793105171"},{"product_id":"rs5-30","title":"RS5\/30 - Duplomatic 3\/4\" BSP bidirectional throttle valve, 80 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS5\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\/4\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 3\/4\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e86 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e132.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS5\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS5\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for in-line installation with 3\/4\" BSP ports. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e80 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e400 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThe threaded body is supplied for direct installation in the hydraulic line. Body dimensions are C = 86 mm, D = 40 mm and E max = 132.5 mm; adjustment knob diameter is 100 mm. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190547804464,"sku":"RS5\/30","price":140.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs5-30-cad.jpg?v=1793105176"},{"product_id":"rs5-i-30","title":"RS5-I\/30 - Duplomatic M33x2 cartridge bidirectional throttle valve, 80 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS5-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e5 (3\/4\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M33x2; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e76.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e44 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e130 \/ 130\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-515; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS5-I\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS5-I\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for screw-in mounting in a hydraulic manifold block. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e80 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThis is the \u003cstrong\u003e-I cartridge version\u003c\/strong\u003e, with a M33x2 mounting thread. The 3\/4\" designation indicates equivalent RS nominal size, not a BSP connection on the cartridge. Match the complete cavity drawing, not only the thread. The type 400-515 bonded seal is excluded from supply. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190547837232,"sku":"RS5-I\/30","price":120.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs5-i-30-cad.jpg?v=1793105181"},{"product_id":"rs6-30","title":"RS6\/30 - Duplomatic 1\" BSP bidirectional throttle valve, 150 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS6\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e105 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e167.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS6\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS6\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for in-line installation with 1\" BSP ports. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThe threaded body is supplied for direct installation in the hydraulic line. Body dimensions are C = 105 mm, D = 50 mm and E max = 167.5 mm; adjustment knob diameter is 120 mm. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190548001072,"sku":"RS6\/30","price":240.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs6-30-cad.jpg?v=1793105186"},{"product_id":"rs6-i-30","title":"RS6-I\/30 - Duplomatic M42x2 cartridge bidirectional throttle valve, 150 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS6-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e6 (1\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M42x2; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e52.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3118 \/ 3118\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-516; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS6-I\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS6-I\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for screw-in mounting in a hydraulic manifold block. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThis is the \u003cstrong\u003e-I cartridge version\u003c\/strong\u003e, with a M42x2 mounting thread. The 1\" designation indicates equivalent RS nominal size, not a BSP connection on the cartridge. Match the complete cavity drawing, not only the thread. The type 400-516 bonded seal is excluded from supply. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190548066608,"sku":"RS6-I\/30","price":230.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs6-i-30-cad.jpg?v=1793105191"},{"product_id":"rs7-30","title":"RS7\/30 - Duplomatic 1 1\/4\" BSP bidirectional throttle valve, 200 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS7\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1 1\/4\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e200 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1 1\/4\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e172.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS7\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS7\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for in-line installation with 1 1\/4\" BSP ports. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e200 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThe threaded body is supplied for direct installation in the hydraulic line. Body dimensions are C = 120 mm, D = 55 mm and E max = 172.5 mm; adjustment knob diameter is 120 mm. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190548132144,"sku":"RS7\/30","price":330.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs7-30-cad.jpg?v=1793105195"},{"product_id":"rs8-30","title":"RS8\/30 - Duplomatic 1 1\/2\" BSP bidirectional throttle valve, 220 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRS8\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBidirectional throttle flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RS series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1 1\/2\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e220 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1 1\/2\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAdjustable throttling in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eGood sealing when fully closed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e134 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e181 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RS8\/30 bidirectional throttle valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRS8\/30\u003c\/strong\u003e is a manually adjustable throttle flow control valve for in-line installation with 1 1\/2\" BSP ports. A conical throttle operating in a cylindrical seat regulates flow in both directions. The standard hand knob is included and can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e220 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. These catalogue values are measured with mineral oil at 36 cSt and 50 °C. Flow through a throttle depends on pressure drop, opening and oil viscosity; this valve does not provide pressure-compensated flow regulation or a free-flow check-valve bypass. Fully closing the valve provides good sealing for flow shut-off.\u003c\/p\u003e\u003cp\u003eThe threaded body is supplied for direct installation in the hydraulic line. Body dimensions are C = 134 mm, D = 65 mm and E max = 181 mm; adjustment knob diameter is 120 mm. Standard NBR seals are intended for HL\/HM mineral hydraulic oil; the FPM option carries the separate \/V suffix.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supplies Duplomatic RS throttle valves for hydraulic speed and flow adjustment. Match the installation type, connection or cavity, flow requirement and pressure before ordering. The CAD view is the primary image; the supplementary photograph illustrates the corresponding series construction. Availability and delivery are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68190548197680,"sku":"RS8\/30","price":370.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rs8-30-cad.jpg?v=1793105199"},{"product_id":"rsn2-30","title":"RSN2\/30 - Duplomatic 1\/4\" BSP throttle check valve, 15 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN2\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\/4\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e15 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e35 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eA → B\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eB → A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1\/4\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.25 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e66 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e78 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN2\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN2\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for in-line installation through 1\/4\" BSP ports. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e15 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e35 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e400 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eThe catalogue identifies B → A as the free-flow direction and A → B as the regulated direction. Follow the flow-direction marking on the body. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe in-line body dimensions are C = 66 mm, D = 20 mm and E max = 78 mm; knob diameter is 50 mm. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191743803696,"sku":"RSN2\/30","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn2-30-cad.jpg?v=1793110725"},{"product_id":"rsn2-i-30","title":"RSN2-I\/30 - Duplomatic M20x1.5 cartridge throttle check valve, 15 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN2-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 (1\/4\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e15 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e35 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRadial ports → axial tip port\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAxial tip port → radial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M20x1.5; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.13 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2050 \/ 2050\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-513; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN2-I\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN2-I\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for screw-in installation in a hydraulic manifold block. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e15 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e35 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eFree flow enters through the axial port at the cartridge tip and exits through the radial ports; throttling acts in the reverse direction. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003e-I cartridge\u003c\/strong\u003e uses a M20x1.5 mounting thread. The 1\/4\" reference is its equivalent RSN nominal size, not a BSP port on the cartridge. Use the complete RSN cavity drawing; matching thread size alone is insufficient. Bonded seal type 400-513 is excluded from supply. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191743934768,"sku":"RSN2-I\/30","price":120.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn2-i-30-cad.jpg?v=1793110730"},{"product_id":"rsn3-30","title":"RSN3\/30 - Duplomatic 3\/8\" BSP throttle check valve, 30 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN3\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\/8\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eA → B\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eB → A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 3\/8\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.5 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e79 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e93 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN3\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN3\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for in-line installation through 3\/8\" BSP ports. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e30 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e80 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e400 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eThe catalogue identifies B → A as the free-flow direction and A → B as the regulated direction. Follow the flow-direction marking on the body. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe in-line body dimensions are C = 79 mm, D = 25 mm and E max = 93 mm; knob diameter is 70 mm. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191743967536,"sku":"RSN3\/30","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn3-30-cad.jpg?v=1793110735"},{"product_id":"rsn3-i-30","title":"RSN3-I\/30 - Duplomatic M27x2 cartridge throttle check valve, 30 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN3-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3 (3\/8\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRadial ports → axial tip port\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAxial tip port → radial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M27x2; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.25 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e70 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e40 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2062 \/ 2062\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-520; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN3-I\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN3-I\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for screw-in installation in a hydraulic manifold block. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e30 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e80 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eFree flow enters through the axial port at the cartridge tip and exits through the radial ports; throttling acts in the reverse direction. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003e-I cartridge\u003c\/strong\u003e uses a M27x2 mounting thread. The 3\/8\" reference is its equivalent RSN nominal size, not a BSP port on the cartridge. Use the complete RSN cavity drawing; matching thread size alone is insufficient. Bonded seal type 400-520 is excluded from supply. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191744164144,"sku":"RSN3-I\/30","price":140.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn3-i-30-cad.jpg?v=1793110739"},{"product_id":"rsn4-30","title":"RSN4\/30 - Duplomatic 1\/2\" BSP throttle check valve, 50 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN4\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\/2\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eA → B\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eB → A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1\/2\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.75 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e94.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e107 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN4\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN4\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for in-line installation through 1\/2\" BSP ports. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e50 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e400 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eThe catalogue identifies B → A as the free-flow direction and A → B as the regulated direction. Follow the flow-direction marking on the body. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe in-line body dimensions are C = 94.5 mm, D = 30 mm and E max = 107 mm; knob diameter is 80 mm. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191744393520,"sku":"RSN4\/30","price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn4-30-cad.jpg?v=1793110745"},{"product_id":"rsn4-i-30","title":"RSN4-I\/30 - Duplomatic M33x2 cartridge throttle check valve, 50 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN4-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 (1\/2\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRadial ports → axial tip port\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAxial tip port → radial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M33x2; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.34 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e44.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e130 \/ 130\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-515; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN4-I\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN4-I\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for screw-in installation in a hydraulic manifold block. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e50 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eFree flow enters through the axial port at the cartridge tip and exits through the radial ports; throttling acts in the reverse direction. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003e-I cartridge\u003c\/strong\u003e uses a M33x2 mounting thread. The 1\/2\" reference is its equivalent RSN nominal size, not a BSP port on the cartridge. Use the complete RSN cavity drawing; matching thread size alone is insufficient. Bonded seal type 400-515 is excluded from supply. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191744557360,"sku":"RSN4-I\/30","price":170.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn4-i-30-cad.jpg?v=1793110751"},{"product_id":"rsn5-30","title":"RSN5\/30 - Duplomatic 3\/4\" BSP throttle check valve, 80 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN5\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3\/4\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eA → B\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eB → A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 3\/4\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1.6 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e115 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e132.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN5\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN5\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for in-line installation through 3\/4\" BSP ports. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e80 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e200 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e400 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eThe catalogue identifies B → A as the free-flow direction and A → B as the regulated direction. Follow the flow-direction marking on the body. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe in-line body dimensions are C = 115 mm, D = 40 mm and E max = 132.5 mm; knob diameter is 100 mm. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191744590128,"sku":"RSN5\/30","price":140.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn5-30-cad.jpg?v=1793110758"},{"product_id":"rsn5-i-30","title":"RSN5-I\/30 - Duplomatic M42x2 cartridge throttle check valve, 80 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN5-I\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e5 (3\/4\" equivalent size)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-block screw-in cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRadial ports → axial tip port\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAxial tip port → radial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCartridge thread M42x2; cavity per catalogue\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.62 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHeight above mounting plane, G max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eInsert length, H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e52.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHexagon, CH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eO-ring \/ backup ring type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3118 \/ 3118\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBonded seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eType 400-516; not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN5-I\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN5-I\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for screw-in installation in a hydraulic manifold block. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e80 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e200 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eFree flow enters through the axial port at the cartridge tip and exits through the radial ports; throttling acts in the reverse direction. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003e-I cartridge\u003c\/strong\u003e uses a M42x2 mounting thread. The 3\/4\" reference is its equivalent RSN nominal size, not a BSP port on the cartridge. Use the complete RSN cavity drawing; matching thread size alone is insufficient. Bonded seal type 400-516 is excluded from supply. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191744622896,"sku":"RSN5-I\/30","price":210.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn5-i-30-cad.jpg?v=1793110763"},{"product_id":"rsn6-30","title":"RSN6\/30 - Duplomatic 1\" BSP throttle check valve, 150 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN6\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e150 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e300 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eA → B\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eB → A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3.05 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e138.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e167.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN6\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN6\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for in-line installation through 1\" BSP ports. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e150 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e300 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eThe catalogue identifies B → A as the free-flow direction and A → B as the regulated direction. Follow the flow-direction marking on the body. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe in-line body dimensions are C = 138.5 mm, D = 50 mm and E max = 167.5 mm; knob diameter is 120 mm. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191744819504,"sku":"RSN6\/30","price":290.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn6-30-cad.jpg?v=1793110768"},{"product_id":"rsn7-30","title":"RSN7\/30 - Duplomatic 1 1\/4\" BSP throttle check valve, 200 l\/min","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRSN7\/30\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eThrottle check valve, one-way flow control\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size (RSN series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1 1\/4\" BSP\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIn-line, threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e200 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow, free-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e400 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCheck valve opening pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRegulated flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eA → B\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFree-flow direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eB → A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 × 1 1\/4\" BSP threaded ports\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR, standard version without V suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHand knob with transverse locking grub screw\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eShut-off function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRegulated direction only; reverse free flow remains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3.75 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHL \/ HM mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody length, C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e157 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBody section, D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum overall height, E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e172.5 mm\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eKnob diameter, ØF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic RSN7\/30 throttle check valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eRSN7\/30\u003c\/strong\u003e combines an adjustable throttle with a check-valve bypass for in-line installation through 1 1\/4\" BSP ports. The conical throttle regulates flow in one direction while the opposite direction has free return. The included hand knob can be locked with the transverse grub screw.\u003c\/p\u003e\u003cp\u003eNominal flow is \u003cstrong\u003e200 l\/min\u003c\/strong\u003e, maximum free-flow capacity is \u003cstrong\u003e400 l\/min\u003c\/strong\u003e and maximum operating pressure is \u003cstrong\u003e320 bar\u003c\/strong\u003e. The check valve opens at 0.35 bar. Catalogue performance values use mineral oil at 36 cSt and 50 °C; actual metered flow depends on pressure drop, knob opening and oil viscosity.\u003c\/p\u003e\u003cp\u003eThe catalogue identifies B → A as the free-flow direction and A → B as the regulated direction. Follow the flow-direction marking on the body. Full closure provides good sealing in the regulated direction; the reverse check-valve path remains available.\u003c\/p\u003e\u003cp\u003eThe in-line body dimensions are C = 157 mm, D = 55 mm and E max = 172.5 mm; knob diameter is 120 mm. Standard NBR seals suit HL\/HM mineral hydraulic oil. IMPEX CONNECT supplies Duplomatic RSN valves with the matching catalogue and CAD reference. Delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68191745016112,"sku":"RSN7\/30","price":370.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rsn7-30-cad.jpg?v=1793110773"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/collections\/hydraulic-flow-control-valves.png?v=1792491327","url":"https:\/\/impex-connect.com\/collections\/flow-control-valves.oembed?page=3","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}