{"product_id":"dsp5-ta02-10n-ei-a110k1","title":"DSP5-TA02\/10N-EI\/A110K1 - Duplomatic NG10 vorgesteuertes Wegeventil, 110 V AC","description":"\u003ch2\u003eTechnische Daten\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eHersteller\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBestellcode\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDSP5-TA02\/10N-EI\/A110K1\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eVentiltyp\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eVorgesteuertes, elektromagnetisch betätigtes Wegeventil\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNenngröße\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNG10 \/ CETOP P05\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAnschlussbild\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCETOP 4.2-4 P05-350\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSchieber \/ Funktion\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eTA02 \/ 4\/2, Federrückstellung, offene Übergangsstellung\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eElektromagnete \/ Schaltstellungen\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1 \/ 2\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eVersorgungsspannung\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e110 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSteuerölversorgung\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eE — Externe Steuerölversorgung über X\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eLeckölführung\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eI — Interne Leckölführung nach T\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDruckgrenze der Hauptstufe P \/ A \/ B\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximaler Eingangsdruck P bei dieser Steuerölversorgung\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximaler Druck T\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e160 bar\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximaler Druck Y\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNicht verwendet: interne Leckölführung\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximaler Volumenstrom bei 210 bar\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e150 l\/min\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximaler Volumenstrom bei 350 bar\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e120 l\/min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSteuerdruckbereich\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMindestens 5–12 bar, abhängig vom Volumenstrom; maximal 210 bar\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDichtungen \/ Hydraulikmedium\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N) \/ HL, HM — ISO 6743-4\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eElektrischer Anschluss\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eK1 — EN 175301-803; Gegenstecker separat bestellen\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eEinschaltdauer \/ Spannungstoleranz\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e100% ED \/ ±10%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSchutzart\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eIP65 mit korrekt verdrahtetem und montiertem Gegenstecker\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMasse laut Katalog\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e5,9 kg\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eTemperatur des Hydraulikmediums\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e−20 bis +80 °C\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eUmgebungstemperatur\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e−20 bis +50 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViskosität \/ empfohlener Wert\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eReinheitsklasse des Hydraulikmediums\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999 — 20\/18\/15\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eBefestigungsschrauben \/ Anziehdrehmoment\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e4 × M6 × 35; 8 Nm (8.8), 12 Nm (10.9)\u003c\/td\u003e\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eVerfügbarkeit\u003c\/th\u003e\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAuf Bestellung; Lieferzeit auf Anfrage\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DSP5-TA02\/10N-EI\/A110K1 NG10-Hydraulik-Wegeventil\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDSP5-TA02\/10N-EI\/A110K1\u003c\/strong\u003e ist ein standardmäßiges, vorgesteuertes Wegeventil der Baureihe DSP5 10 mit elektromagnetischer Betätigung, NBR-Dichtungen und elektrischen K1-Anschlüssen. Der Schieber TA02 bietet die Funktion \u003cstrong\u003e4\/2, Federrückstellung, offene Übergangsstellung\u003c\/strong\u003e. Prüfen Sie sämtliche Strömungswege anhand des Hydrauliksymbols im Katalog. Das Ventil verfügt über einen Elektromagneten, zwei Schaltstellungen und eine Versorgung mit 110 V AC. Es eignet sich bei Einhaltung der Kataloggrenzen für industrielle Hydraulikaggregate, Werkzeugmaschinen und andere Maschinen.\u003c\/p\u003e\u003ch3\u003eSteuerölversorgung, Leckölführung und Betriebsgrenzen\u003c\/h3\u003e\u003cp\u003eExterne Steuerölversorgung über X. Interne Leckölführung nach T. Der Steuerdruck muss je nach Volumenstrom mindestens 5–12 bar und höchstens 210 bar betragen. Der Steuerölrücklauf ist mit T verbunden; der Druck an T darf 160 bar nicht überschreiten. Die Volumenstromgrenze beträgt 150 l\/min bei 210 bar und 120 l\/min bei 350 bar, abhängig von Schieber und Schaltung. Dies sind Betriebsgrenzen und keine Nennvolumenströme.\u003c\/p\u003e\u003ch3\u003eMontage und technische Dokumentation\u003c\/h3\u003e\u003cp\u003eDSP5 verwendet das Anschlussbild CETOP P05. DSP5R besitzt eine andere Anschlussanordnung und ist nicht ohne Prüfung austauschbar. Prüfen Sie vor der Bestellung die Einbauzeichnung, die Verschlussstopfen der Steueröl- und Leckölkanäle, die Druck- und Volumenstromgrenzen sowie die Versorgungsspannung. Elektrische Gegenstecker sind nicht enthalten. CAD-Modell und Abbildung zeigen die passende äußere Magnetanordnung; Schieberfunktion und interne Steueröl-\/Leckölkonfiguration werden durch den Bestellcode festgelegt.\u003c\/p\u003e\u003cp\u003eAC-Spulennennwerte: 110 V \/ 50 Hz; 120 V \/ 60 Hz.\u003c\/p\u003e\u003ch3\u003eOptionale Ausführungen auf Anfrage\u003c\/h3\u003e\u003cp\u003eDer Katalog beschreibt außerdem Hochdruckausführungen H, Steuerdruckminderung Z, Hubbegrenzung C, Schaltzeiteinstellung D, Dämpfung P08, Steuerölentlastung S2 sowie besondere Dichtungen oder Schutzbehandlungen. Diese Optionen sind in diesem Standardartikel nicht enthalten. Verfügbarkeit und Kompatibilität müssen separat bestätigt werden.\u003c\/p\u003e\u003cp\u003eFordern Sie DSP5-TA02\/10N-EI\/A110K1 bei IMPEX CONNECT für die internationale B2B-Beschaffung an. Angezeigte Preise verstehen sich zzgl. MwSt. Verfügbarkeit und Lieferbedingungen werden mit dem Angebot bestätigt.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68485038604592,"sku":"DSP5-TA02\/10N-EI\/A110K1","price":424.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-dsp5-side-a-ac-cad.jpg?v=1795118155","url":"https:\/\/impex-connect.com\/de\/products\/dsp5-ta02-10n-ei-a110k1","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}