{"product_id":"duplomatic-rlm3a-a04-21n-d12k1","title":"RLM3A-A04\/21N-D12K1 - Duplomatic NG6 Eilgang-\/Schleichgangventil","description":"\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHersteller\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eModell\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eRLM3A-A04\/21N-D12K1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eVentiltyp\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eElektrisches Ventil zur schnellen\/langsamen Geschwindigkeitsauswahl\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNenngröße\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG6 \/ CETOP 03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eMontage\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSandwich \/ modular, ISO 4401-03-02-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eMaximaler Betriebsdruck\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e250 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eVolumenstromregelung\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eAblaufdrosselung-Regelung aus Stellkammer A\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eEinstellbereich des Schleichgang-Volumenstroms\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0,025-4 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eMagnetbetätigtes Bypassventil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNormalerweise offen (NO)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eMaximaler Volumenstrom in den freien Leitungen\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e65 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStromloser Zustand\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSchneller \/ Bypass-Durchfluss\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBestromter Zustand\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eLangsamer \/ geregelter Durchfluss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eVersorgungsspannung\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC, ±10 %\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSpulenanschluss\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1, EN 175301-803 (ehem. DIN 43650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSpulenleistung\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e22 W\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNennstrom\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1,84 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eHandnotbetätigung\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eKeine, Standardausführung\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDichtungen\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eUmgebungstemperatur\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e-20 bis +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eTemperatur des Hydraulikmediums\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e-20 bis +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eViskosität des Hydraulikmediums\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; empfohlen: 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eReinheitsklasse\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999 Klasse 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eEinschaltdauer\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100 %\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIP65 mit korrekt installiertem passendem Stecker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSchaltzeit beim Ein- \/ Ausschalten\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e85 \/ 60 ms\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eMasse laut Katalog\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3,1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eVolumenstromeinstellung\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eKalibrierter Drehknopf mit Arretierungsschraube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eBaureihe\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eRLM3A-A04\/21N-D12K1 - Duplomatic elektrisches Ventil zur schnellen\/langsamen Geschwindigkeitsauswahl\u003c\/h2\u003e\u003cp\u003eRLM3A-A04\/21N-D12K1 kombiniert einen RPC1-Durchflussregler mit einem KT08-Magnetventil-Bypassventil zur Umschaltung zwischen schnellem Vorschub und einer einstellbaren Arbeitsgeschwindigkeit. Der Bereich für den langsamen Durchfluss beträgt 0,025-4 l\/min. Die modulare Baugruppe wird unterhalb von ISO 4401-03-Wegeventilen montiert und arbeitet bei Drücken von bis zu 250 bar.\u003c\/p\u003e\u003cp\u003eRLM3A regelt den aus Stellkammer A austretenden Durchfluss. Die gewählte Konfiguration muss zum Stellantriebskreislauf und zum darüberliegenden Wegeventil passen.\u003c\/p\u003e\u003cp\u003eDie A-Version verwendet einen normalerweise offenen (NO) Magnetventil-Bypass: Ohne Stromversorgung stellt das Ventil einen schnellen \/ Bypass-Durchfluss bereit; bei Stromzufuhr stellt es einen langsamen \/ geregelten Durchfluss bereit. Der Wert von 65 l\/min bezieht sich auf freie Leitungen, nicht auf die Nenndurchflussrate für den langsamen Durchfluss. Wählen Sie den Betriebspunkt für den schnellen Durchfluss anhand der Betriebsgrenzkurve im Katalog.\u003c\/p\u003e\u003ch3\u003eElektrischer Anschluss und Installation\u003c\/h3\u003e\u003cp\u003eDiese NBR-Version verwendet eine 12 V DC, 22 W Spule mit K1-Anschluss. Der elektrische Stecker wird separat bestellt; IP65 erfordert einen korrekt angeschlossenen passenden Stecker. NBR-Dichtungen sind für Mineralhydrauliköl HL\/HM vorgesehen. Die Schaltzeiten sind Katalogreferenzwerte, die mit 36 cSt Öl bei 50 °C gemessen wurden. Die herunterladbare CAD-Serie 20 stellt die äußere Montagegeometrie dar; der Katalog gibt an, dass die Gesamt- und Montagedimensionen für die Designserien 20-29 unverändert bleiben. Verfügbarkeit und Lieferzeit werden auf Anfrage bestätigt.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68220553888048,"sku":"RLM3A-A04\/21N-D12K1","price":530.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-rlm3a-a01-20n-d24k1-n-cad.jpg?v=1793375214","url":"https:\/\/impex-connect.com\/de\/products\/duplomatic-rlm3a-a04-21n-d12k1","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}