{"product_id":"ds3-ta02-11n-a110k1-duplomatic-directional-control-valve","title":"DS3-TA02\/11N-A110K1 - Duplomatic directional valve · 110V AC","description":"\u003cp\u003eDuplomatic DS3-TA02\/11N-A110K1 is a direct-operated 4\/2 directional control valve with a single solenoid on side A and spring return. It features an NG6 \/ CETOP 03 mounting interface, 110 V AC \/ 120 V AC supply, NBR seals and a K1 DIN electrical connection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3-TA02\/11N-A110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eDS3\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eTA02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4-way, 2-position\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSingle solenoid, side A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eSpring return\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNG6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05 (CETOP 03)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eAny position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e70 l\/min in standard 4-port operation; see catalogue operating limits\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P, A, B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e160 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e194 VA inrush \/ 44 VA holding (110 V, 50 Hz); 185 VA \/ 42 VA (120 V, 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e+\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with a correctly wired and installed connector of equivalent rating\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eNBR (code N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eMineral oil HL or HM (ISO 6743-4)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid viscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e10-400 cSt; recommended 25 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eStandard override integrated into solenoid tube\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e4 x M5 x 30 (ISO 4762); tightening torque 5 Nm (A8.8)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px 10px 0;border-bottom:1px solid #e1e1e1;\"\u003eOrdered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv style=\"height:24px;\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDuplomatic DS3-TA02\/11N-A110K1 Solenoid Directional Control Valve\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDuplomatic DS3-TA02\/11N-A110K1\u003c\/strong\u003e provides direct solenoid control of hydraulic flow in industrial machinery, power units and OEM systems. The TA02 spool uses one solenoid on \u003cstrong\u003eside A\u003c\/strong\u003e to switch between two external operating positions. A return spring restores the spool when the coil is de-energized.\u003c\/p\u003e\n\u003cp\u003eThis version operates with \u003cstrong\u003e110 V AC \/ 50 Hz; 120 V AC \/ 60 Hz\u003c\/strong\u003e. The standardized \u003cstrong\u003eISO 4401-03 \/ CETOP 03 (NG6)\u003c\/strong\u003e mounting surface supports installation on compatible subplates and hydraulic manifolds. NBR seals suit mineral oil-based HL and HM fluids.\u003c\/p\u003e\n\u003cp\u003eMaximum operating pressure at ports P, A and B is \u003cstrong\u003e350 bar\u003c\/strong\u003e, and the maximum T-port pressure is \u003cstrong\u003e160 bar\u003c\/strong\u003e. The TA02 spool has an open crossover condition during switching. In standard 4-port operation, AC curve 1 specifies flow up to \u003cstrong\u003e70 l\/min\u003c\/strong\u003e. See catalogue section 6.1. Three-port operation, a blocked working port or operation without flow in one working line requires checking section 6.2.\u003c\/p\u003e\n\u003cp\u003eThe K1 coil connection accepts an EN 175301-803 connector (formerly DIN 43650), ordered separately. IP65 protection requires a connector of equivalent rating, correctly wired and installed.\u003c\/p\u003e\n\u003cp\u003eIMPEX CONNECT supplies \u003cstrong\u003eDS3-TA02\/11N-A110K1\u003c\/strong\u003e for industrial hydraulic systems and replacement applications. Consult the attached DS3 catalogue for performance diagrams, installation details and electrical specifications. The dedicated DWG CAD model is available in the 3D Model download field.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68080858628400,"sku":"DS3-TA02\/11N-A110K1","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/DS3-TA02_11N-A110K1_2b3e9c19-5e81-4223-8884-722e4e35cfb4.jpg?v=1792073080","url":"https:\/\/impex-connect.com\/products\/ds3-ta02-11n-a110k1-duplomatic-directional-control-valve","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}