{"product_id":"dse3-a01-11n-d12k1","title":"DSE3-A01\/11N-D12K1 - Duplomatic NG6 proportional directional valve, 1 l\/min, 12 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDSE3-A01\/11N-D12K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect operated proportional directional valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSize \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG6 \/ CETOP 03, subplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eA — open centre\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 solenoids, 3 positions, spring centred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal spool flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal flow reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eΔp 10 bar P→T (catalogue rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum valve flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e40 l\/min (depends on pressure drop)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure, T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal coil voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal coil current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1.88 A\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil resistance at 20 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3.66 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 18\/16\/13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection \/ manual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with connectors fitted \/ integrated pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DSE3-A01\/11N-D12K1 proportional directional valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDSE3-A01\/11N-D12K1\u003c\/strong\u003e is a direct operated proportional directional valve for continuously controlling the direction and speed of hydraulic actuators. This NG6 \/ CETOP 03 execution has a \u003cstrong\u003eopen centre A spool\u003c\/strong\u003e, two 12 V DC proportional solenoids, K1 electrical connections and NBR seals. The three-position spool is centred by springs.\u003c\/p\u003e\u003cp\u003eNominal spool flow is \u003cstrong\u003e1 l\/min\u003c\/strong\u003e, with the catalogue reference pressure drop of Δp 10 bar P→T. The valve's overall maximum flow is 40 l\/min; actual flow depends on pressure drop and command current. Maximum operating pressure is 350 bar at P, A and B, and 210 bar at T.\u003c\/p\u003e\u003cp\u003eUse a suitable current-controlled supply or an external proportional amplifier; the nominal current is 1.88 A per coil. Valve opening is controlled by coil current, so nominal voltage alone is not a proportional control signal. The standard K1 connectors are included in the catalogue supply. NBR seals are specified for HL or HM mineral hydraulic oils. The photo and CAD illustrate the common double-solenoid K1 construction; the ordering code and specifications identify this execution.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDSE3-A01\/11N-D12K1\u003c\/strong\u003e for industrial hydraulic systems. Check spool centre, nominal flow, coil voltage and mounting dimensions when selecting a valve. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68163214967088,"sku":"DSE3-A01\/11N-D12K1","price":330.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-dse3-k1-cad.jpg?v=1792748155","url":"https:\/\/impex-connect.com\/products\/dse3-a01-11n-d12k1","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}