{"product_id":"dse5-c30sb-10n-d12k1","title":"DSE5-C30SB\/10N-D12K1 - Duplomatic NG10 proportional directional valve, 30 l\/min, 12 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDSE5-C30SB\/10N-D12K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect operated proportional directional valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSize \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ CETOP 05, subplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSpool type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eC — closed centre\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1 solenoid on side B, 2 positions, spring return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal spool flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFlow reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eΔp 10 bar P→T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum valve flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e90 l\/min (depends on pressure drop)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure P \/ A \/ B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e320 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum pressure T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e210 bar, standard version\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal coil voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum coil current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2.6 A\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil resistance at 20 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.4 kg\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +60 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 18\/16\/13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIntegrated pin, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DSE5-C30SB\/10N-D12K1 proportional directional valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDSE5-C30SB\/10N-D12K1\u003c\/strong\u003e controls the direction and speed of hydraulic actuators with proportional coil-current control. This NG10 valve has a closed centre C spool, 1 solenoid on side b, 2 positions, spring return, 12 V DC coils, K1 connections and NBR seals.\u003c\/p\u003e\u003cp\u003eNominal spool flow is \u003cstrong\u003e30 l\/min\u003c\/strong\u003e at Δp 10 bar P→T. The overall valve maximum is 90 l\/min; actual flow depends on pressure drop and command current. Maximum pressure is 320 bar at P, A and B, and 210 bar at T for this standard version.\u003c\/p\u003e\u003cp\u003eUse a suitable current-controlled supply or external proportional amplifier. Maximum coil current is 2.6 A per coil; nominal voltage alone is not a proportional command signal. NBR seals are intended for HL\/HM mineral hydraulic oils. CAD files and illustrations show the matching SB K1 construction; the selected ordering code specifies spool flow, centre and voltage.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDSE5-C30SB\/10N-D12K1\u003c\/strong\u003e for industrial hydraulic systems. Check the hydraulic circuit, mounting dimensions and amplifier compatibility before selection. Delivery time is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68175444181296,"sku":"DSE5-C30SB\/10N-D12K1","price":470.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-dse5-sb-k1-cad.jpg?v=1792956757","url":"https:\/\/impex-connect.com\/products\/dse5-c30sb-10n-d12k1","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}