{"product_id":"dsp5-s12-10n-ee-d24k1","title":"DSP5-S12\/10N-EE\/D24K1 - Duplomatic NG10 pilot-operated directional valve, 24 V DC","description":"\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eOrdering code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDSP5-S12\/10N-EE\/D24K1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePilot-operated, solenoid-actuated directional valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNG10 \/ CETOP P05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting surface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCETOP 4.2-4 P05-350\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSpool \/ function\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eS12 \/ 4\/3 closed centre, throttled transition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSolenoids \/ positions\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e2 \/ 3\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePilot supply\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eE — External pilot supply through X\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDrainage\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eE — External drain through Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMain-stage pressure rating P \/ A \/ B\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum inlet P for this pilot arrangement\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum pressure T\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e250 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum pressure Y\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum flow at 210 bar\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e150 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum flow at 350 bar\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e120 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePilot pressure range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e5–12 bar minimum, depending on flow; 210 bar maximum\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals \/ fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N) \/ HL, HM — ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eElectrical connection\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eK1 — EN 175301-803; mating connectors ordered separately\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuty cycle \/ voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e100% ED \/ ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eIP65 with correctly wired and fitted matching connector\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e6.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity \/ recommended\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999 — 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting screws \/ torque\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e4 × M6 × 35; 8 Nm (8.8), 12 Nm (10.9)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAvailability\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eOn order; lead time confirmed on enquiry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DSP5-S12\/10N-EE\/D24K1 NG10 hydraulic directional valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDSP5-S12\/10N-EE\/D24K1\u003c\/strong\u003e is a standard DSP5 series 10 pilot-operated directional valve with solenoid actuation, NBR seals and K1 electrical connections. The S12 spool provides \u003cstrong\u003e4\/3 closed centre, throttled transition\u003c\/strong\u003e; use its catalogue hydraulic symbol to confirm all flow paths. The valve has two solenoids, 3 positions and 24 V DC supply. It is suitable for industrial hydraulic power units, machine tools and machinery when selected within the catalogue limits.\u003c\/p\u003e\u003ch3\u003ePilot supply, drainage and operating limits\u003c\/h3\u003e\u003cp\u003eExternal pilot supply through X. External drain through Y. Pilot pressure must be at least 5–12 bar, depending on flow, and no more than 210 bar. Route Y separately to tank and keep Y pressure within 210 bar. The flow limit is 150 l\/min at 210 bar and 120 l\/min at 350 bar, subject to the selected spool and circuit. These are operating limits, not nominal flow ratings.\u003c\/p\u003e\u003ch3\u003eMounting and technical documentation\u003c\/h3\u003e\u003cp\u003eDSP5 uses the CETOP P05 mounting surface. DSP5R has a different port layout and must not be assumed interchangeable. Check the mounting drawing, pilot\/drain plugs, pressure–flow limits and electrical supply before ordering. Mating electrical connectors are not included. The CAD model and image represent the corresponding external solenoid arrangement; the exact spool function and internal pilot\/drain configuration are specified by the ordering code.\u003c\/p\u003e\u003ch3\u003eOptional executions on request\u003c\/h3\u003e\u003cp\u003eThe catalogue also describes high-pressure H versions, Z pilot-pressure reduction, C stroke control, D switching-time control, P08 damping, S2 pilot unloading and special seals or protective treatments. These options are not included in this standard product. Availability and compatibility require separate confirmation.\u003c\/p\u003e\u003cp\u003eRequest DSP5-S12\/10N-EE\/D24K1 from IMPEX CONNECT for international B2B supply. Prices, where displayed, exclude VAT. Availability and delivery terms are confirmed with the quotation.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68484762730800,"sku":"DSP5-S12\/10N-EE\/D24K1","price":477.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-dsp5-dual-dc-cad.jpg?v=1795118122","url":"https:\/\/impex-connect.com\/products\/dsp5-s12-10n-ee-d24k1","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}