{"product_id":"dsp5-sa3-10n-ie-d24k1","title":"DSP5-SA3\/10N-IE\/D24K1 - Duplomatic NG10 pilot-operated directional valve, 24 V DC","description":"\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eOrdering code\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDSP5-SA3\/10N-IE\/D24K1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eValve type\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePilot-operated, solenoid-actuated directional valve\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNG10 \/ CETOP P05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting surface\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCETOP 4.2-4 P05-350\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSpool \/ function\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSA3 \/ 4\/2 float at rest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSolenoids \/ positions\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e1 \/ 2\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePilot supply\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eI — Internal pilot supply from P\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDrainage\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eE — External drain through Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMain-stage pressure rating P \/ A \/ B\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e350 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum inlet P for this pilot arrangement\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum pressure T\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e250 bar\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum pressure Y\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e210 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum flow at 210 bar\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e150 l\/min\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMaximum flow at 350 bar\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e120 l\/min — external pilot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003ePilot pressure range\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e5–12 bar minimum, depending on flow; 210 bar maximum\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eSeals \/ fluid\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eNBR (N) \/ HL, HM — ISO 6743-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eElectrical connection\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eK1 — EN 175301-803; mating connectors ordered separately\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eDuty cycle \/ voltage tolerance\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e100% ED \/ ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eIP65 with correctly wired and fitted matching connector\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eCatalogue mass\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e5.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eViscosity \/ recommended\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eFluid cleanliness\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eISO 4406:1999 — 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eMounting screws \/ torque\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003e4 × M6 × 35; 8 Nm (8.8), 12 Nm (10.9)\u003c\/td\u003e\n\u003cth scope=\"row\" style=\"width:25%;padding:10px;text-align:left;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eAvailability\u003c\/th\u003e\n\u003ctd style=\"width:25%;padding:10px;vertical-align:top;border-bottom:1px solid #e1e1e1;overflow-wrap:anywhere\"\u003eOn order; lead time confirmed on enquiry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DSP5-SA3\/10N-IE\/D24K1 NG10 hydraulic directional valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDSP5-SA3\/10N-IE\/D24K1\u003c\/strong\u003e is a standard DSP5 series 10 pilot-operated directional valve with solenoid actuation, NBR seals and K1 electrical connections. The SA3 spool provides \u003cstrong\u003e4\/2 float at rest\u003c\/strong\u003e; use its catalogue hydraulic symbol to confirm all flow paths. The valve has one solenoid, 2 positions and 24 V DC supply. It is suitable for industrial hydraulic power units, machine tools and machinery when selected within the catalogue limits.\u003c\/p\u003e\u003ch3\u003ePilot supply, drainage and operating limits\u003c\/h3\u003e\u003cp\u003eInternal pilot supply from P. External drain through Y. Pilot pressure must be at least 5–12 bar, depending on flow, and no more than 210 bar. Internal pilot supply therefore limits inlet P to 210 bar; a 350 bar main-stage rating does not permit 350 bar at the pilot stage. Route Y separately to tank and keep Y pressure within 210 bar. The flow limit is 150 l\/min at 210 bar and 120 l\/min at 350 bar, subject to the selected spool and circuit. These are operating limits, not nominal flow ratings.\u003c\/p\u003e\u003cp\u003eOperation at 350 bar inlet pressure requires a separately selected external-pilot arrangement or a suitable optional pressure-reducing version. This product is the standard internal-pilot version.\u003c\/p\u003e\u003ch3\u003eMounting and technical documentation\u003c\/h3\u003e\u003cp\u003eDSP5 uses the CETOP P05 mounting surface. DSP5R has a different port layout and must not be assumed interchangeable. Check the mounting drawing, pilot\/drain plugs, pressure–flow limits and electrical supply before ordering. Mating electrical connectors are not included. The CAD model and image represent the corresponding external solenoid arrangement; the exact spool function and internal pilot\/drain configuration are specified by the ordering code.\u003c\/p\u003e\u003ch3\u003eOptional executions on request\u003c\/h3\u003e\u003cp\u003eThe catalogue also describes high-pressure H versions, Z pilot-pressure reduction, C stroke control, D switching-time control, P08 damping, S2 pilot unloading and special seals or protective treatments. These options are not included in this standard product. Availability and compatibility require separate confirmation.\u003c\/p\u003e\u003cp\u003eRequest DSP5-SA3\/10N-IE\/D24K1 from IMPEX CONNECT for international B2B supply. Prices, where displayed, exclude VAT. Availability and delivery terms are confirmed with the quotation.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68484912873776,"sku":"DSP5-SA3\/10N-IE\/D24K1","price":404.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-dsp5-side-a-dc-cad.jpg?v=1795118151","url":"https:\/\/impex-connect.com\/products\/dsp5-sa3-10n-ie-d24k1","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}