{"product_id":"dt03-2h-11n-r110k1","title":"DT03-2H\/11N-R110K1 - Duplomatic NG6 2\/2 normally open poppet directional valve, 110V AC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDT03-2H\/11N-R110K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect operated poppet directional control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG6 \/ CETOP 03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHydraulic configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\/2; scheme 2H\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eControl \/ Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2\/2 normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDe-energized connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP connected to T\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eEnergized connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP and T blocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eActive ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eP \/ T\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSolenoid \/ return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eOne solenoid on side A; spring return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e250 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum flow for this version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e25 l\/min; operating-limit curve 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e110 V AC, 50\/60 Hz, bridge rectifier required\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e22 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eConnector \/ rectifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eConnector not supplied; bridge rectifier mandatory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eStandard manual override\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +50 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 20\/18\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ voltage tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ ±10%\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIP65 with correctly installed connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSwitching time, on \/ off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e30 \/ 50 ms at catalogue test conditions\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4 × M5 × 50; tightening torque 5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic DT03-2H\/11N-R110K1 NG6 poppet directional valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDT03-2H\/11N-R110K1\u003c\/strong\u003e is a direct operated solenoid poppet valve with a conical seat, 2\/2 configuration and spring return. Scheme 2H provides \u003cstrong\u003e2\/2 normally open\u003c\/strong\u003e. De-energized: P connected to T. Energized: P and T blocked. The two-way design provides bidirectional sealing.\u003c\/p\u003e\u003cp\u003eMaximum operating pressure is 250 bar. This version follows operating-limit curve 1, with flow up to 25 l\/min; permissible flow decreases with pressure. The family rating of 25 l\/min does not apply to every execution. The R110 coil is for a 110 V AC, 50\/60 Hz supply with a bridge rectifier in a type D connector or an external rectifier. Do not connect the coil directly to AC. The connector and rectifier must be ordered separately.\u003c\/p\u003e\u003cp\u003eDuring switching, all valve flow paths are interconnected. With accumulator supply or high-delivery pumps, use suitable orifices on the accumulator side to limit flow to 12 l\/min, while respecting the version-specific operating limits. This standard product has no optional D08\/D10 port-P orifice.\u003c\/p\u003e\u003cp\u003eNBR seals suit mineral hydraulic oil. The primary CAD view and downloadable DWG represent the external side-A construction shared by 3C, 3D, 2E and 2H in the catalogue. The supplied CAD reference is D24; the ordering code specifies the hydraulic function and electrical equipment. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eDT03-2H\/11N-R110K1\u003c\/strong\u003e for industrial hydraulic systems. delivery is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68189219094832,"sku":"DT03-2H\/11N-R110K1","price":320.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-dt03-side-a-cad.jpg?v=1793098427","url":"https:\/\/impex-connect.com\/products\/dt03-2h-11n-r110k1","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}