{"product_id":"pde3-025-10n-d12k1-duplomatic-proportional-pressure-relief-valve-modular-design-cetop-03-25-bar-2-l-min-12v-dc","title":"PDE3-025\/10N-D12K1 - Duplomatic NG6 proportional pressure relief valve, 0.9-25 bar, 12 V DC, NBR","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003ePDE3-025\/10N-D12K1\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDirect operated proportional pressure relief valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eSubplate mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG6 \/ CETOP 03\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-03-02-0-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePressure control range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e0.9-25 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure, P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum T-line backpressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal \/ maximum flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1 \/ 2 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal coil voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal coil current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1.88 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil resistance at 20 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3.66 Ω\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 - EN 175301-803 (DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eProtection \/ insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eIP65 \/ class H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e-20 to +60 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e-20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10-400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 18\/16\/13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHysteresis (PWM 200 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u0026lt;5% of nominal pressure\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u0026lt; ±1.5% of nominal pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic PDE3-025\/10N-D12K1 proportional pressure relief valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePDE3-025\/10N-D12K1\u003c\/strong\u003e is a direct operated proportional pressure relief valve for electrical pressure regulation and pilot control of two-stage hydraulic valves. The subplate mounting interface is ISO 4401-03 \/ CETOP 03 \/ NG6. This execution has a \u003cstrong\u003e0.9-25 bar pressure control range\u003c\/strong\u003e, a 12 V DC coil and NBR seals.\u003c\/p\u003e\u003cp\u003eMaximum operating pressure at port P is 350 bar; this is distinct from the pressure control range of the selected execution. Nominal flow is 1 l\/min and maximum flow is 2 l\/min. Factory full-scale pressure is set at 1 l\/min. At higher flow rates, full-scale pressure rises considerably; minimum controlled pressure also depends on flow. Connect T directly to tank: permissible operating backpressure is 2 bar and any T-line backpressure adds to the controlled pressure.\u003c\/p\u003e\u003cp\u003eUse a suitable current-controlled supply or external proportional amplifier. Nominal coil current is 1.88 A. The valve incorporates a mechanical pressure-limiting feature; it has no integrated electronic controller. Compatible catalogue amplifiers include EDC-142 and EDM-M142. The K1 connector to EN 175301-803 is included in the catalogue supply. NBR seals (N) are specified for HL or HM mineral hydraulic oils according to ISO 6743-4.\u003c\/p\u003e\u003cp\u003eIMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003ePDE3-025\/10N-D12K1\u003c\/strong\u003e for industrial hydraulic systems. Confirm the pressure range, coil voltage, seal material and mounting dimensions when selecting a replacement. Availability and delivery time are confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":67833451741488,"sku":"PDE3-025\/10N-D12K1","price":289.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-pde3-k1-cad-3d-view.jpg?v=1792957261","url":"https:\/\/impex-connect.com\/products\/pde3-025-10n-d12k1-duplomatic-proportional-pressure-relief-valve-modular-design-cetop-03-25-bar-2-l-min-12v-dc","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}