{"product_id":"qde5-80-11n-d12k1-ck","title":"QDE5-80\/11N-D12K1\/CK - Duplomatic proportional flow control valve, 80 l\/min, 12 V DC","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:40px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eQDE5-80\/11N-D12K1\/CK\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eDuplomatic MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eValve type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eProportional pressure-compensated flow control valve\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNG10 \/ ISO 4401-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eControlled flow QB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eUp to 80 l\/min\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum input flow QA, 3-port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e90 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMaximum operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e250 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMinimum pressure drop A→B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e22 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCompensator spring setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e8 bar\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2- or 3-port, defined by subplate passages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal coil voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e12 V DC\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eNominal coil current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCoil resistance at 20 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e3 Ω\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003ePWM frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eK1 — EN 175301-803 (ex DIN 43650)\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eManual override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eCK knob manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eSeal material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eNBR (N), for mineral hydraulic oil\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eCatalogue mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e4.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eDuty cycle \/ valve protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e100% \/ IP65 with suitable connector installed\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eMounting interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4401-05-04-0-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +60 °C\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e−20 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eViscosity range \/ recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e10–400 \/ 25 cSt\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eFluid cleanliness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003eISO 4406:1999, class 18\/16\/13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u0026lt;6% of maximum controlled flow\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:25%;padding:10px 12px;border-bottom:1px solid #e1e1e1;\"\u003e\u0026lt;±2% of maximum controlled flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDuplomatic QDE5-80\/11N-D12K1\/CK proportional flow control valve\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQDE5-80\/11N-D12K1\/CK\u003c\/strong\u003e is a direct operated, pressure-compensated proportional flow control valve for hydraulic branch-flow regulation and actuator speed control. The selected execution controls flow A→B up to \u003cstrong\u003e80 l\/min\u003c\/strong\u003e, with a 12 V DC coil, K1 connection and NBR seals. The \/CK knob provides manual override.\u003c\/p\u003e\u003cp\u003eThe same valve can operate with two or three ports, depending on the mounting plate passages. The T passage must not be connected to tank; the P passage is provided only for three-port operation. Maximum inlet flow QA in three-port operation is 90 l\/min, distinct from controlled outlet flow QB of 80 l\/min. Maximum working pressure is 250 bar and the minimum pressure drop A→B is 22 bar for this flow range.\u003c\/p\u003e\u003cp\u003eUse a current-controlled supply or an appropriate external amplifier, such as EDC-151 \/ EDM-M151. Nominal coil current is 2.8 A and the specified PWM frequency is 100 Hz. Coil voltage alone is not a proportional command signal. Pressure compensation maintains the regulated flow against load-pressure changes within the catalogue operating conditions.\u003c\/p\u003e\u003cp\u003eThe zinc-nickel coated body mounts on ISO 4401-05-04-0-05. NBR seals are intended for HL\/HM mineral hydraulic oils. The CAD image and DWG correspond to the knob-equipped CK K1 construction. IMPEX CONNECT supports international B2B sourcing of \u003cstrong\u003eQDE5-80\/11N-D12K1\/CK\u003c\/strong\u003e for industrial hydraulic systems. Confirm subplate porting, flow range and amplifier compatibility; delivery time is confirmed on request.\u003c\/p\u003e","brand":"Duplomatic MS","offers":[{"title":"Default Title","offer_id":68180548682032,"sku":"QDE5-80\/11N-D12K1\/CK","price":652.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/6227\/3840\/files\/duplomatic-qde5-ck-cad.jpg?v=1793008756","url":"https:\/\/impex-connect.com\/products\/qde5-80-11n-d12k1-ck","provider":"IMPEX CONNECT DOO","version":"1.0","type":"link"}