Duplomatic EDC-1 digital plug-in amplifier with standard EN 175301-803 DIN connection

EDC-102/10E2 - Duplomatic plug-in proportional valve amplifier

€145,95
Bez PDV-a
Pošaljite upit

Dostupnost i uslovi isporuke potvrđuju se putem imejla na zahtev.

Pošaljite ovaj upit o proizvodu direktno putem e-pošte

Preuzimanja


Opis proizvoda

Specifications

Part number EDC-102/10E2 Brand Duplomatic MS
Amplifier type Digital open-loop proportional valve amplifier Channels 1 proportional solenoid
Command signal 0–5 V Power supply 10–30 V DC, ripple included
Factory maximum current 780 mA Factory PWM frequency 200 Hz
Maximum current adjustment 390–780 mA PWM adjustment 50–500 Hz
Mounting Direct plug-in on valve coil Valve-side connection EN 175301-803 (DIN 43650)
PLC-side connection Standard EN 175301-803, 3 pins + earth Signal input impedance 100 kΩ
Ramp up / ramp down Independently adjustable, 0–50 s Offset adjustment 0–390 mA
Protection rating IP65/IP67 according to catalogue Operating temperature −20 to +70 °C
Configuration On-board buttons and display; optional EDCPC/10 kit Mass 0.10 kg
Catalogue 89 120/124 ED — series 10 Availability On order

EDC-102/10E2 Duplomatic plug-in proportional valve amplifier

EDC-102/10E2 is a digital current amplifier for open-loop control of one proportional hydraulic valve solenoid. This series 10 execution has a 0–5 V command input, a factory maximum current of 780 mA and a factory PWM setting of 200 Hz. It mounts directly on the valve coil connection to EN 175301-803 (DIN 43650), with the standard DIN connector on the PLC side.

Control and adjustment

The amplifier regulates solenoid current in proportion to the reference signal and compensates for changes in temperature and load impedance. PWM control reduces valve hysteresis. Adjust maximum current, offset, PWM frequency and independent acceleration and deceleration ramps using the on-board buttons and display. The optional EDCPC/10 configuration kit, code 3898301001, is ordered separately.

Valve selection and installation

Select the amplifier maximum current and PWM frequency against the exact valve coil specification. One EDC-1 controls one solenoid; a two-solenoid valve requires two amplifiers and suitable command logic. Valves with integrated electronics use their own electronic driver. The regulated and filtered supply must remain within 10–30 V DC, including ripple, and must be higher than the connected solenoid's rated working voltage, as specified in the manufacturer catalogue. Required power depends on supply voltage and output current.

This ordering code uses the standard DIN connection on the PLC side. The voltage input is 0–5 V; use a matching controller output. Download the manufacturer datasheet for wiring, dimensions and commissioning instructions. IMPEX CONNECT supplies EDC-102/10E2 on order for industrial hydraulic applications; delivery is confirmed with your quotation.