Product Description
| Manufacturer | Duplomatic MS | Ordering code | DSP7-TB02/20N-CI/D24K1 |
| Valve type | Pilot-operated directional control valve | Nominal size | NG16 / CETOP 07 |
| Mounting surface | ISO 4401-07-07-0-05 | Spool / function | TB02 / 4/2 spring return, open crossover |
| Solenoids | 1 | Power supply | 24V DC |
| Pilot supply | C — Internal pilot supply with backpressure valve in P | Drainage | I — Internal drain to T |
| Max. pressure P / A / B | 350 bar; pilot limits also apply | Max. pressure T | 210 bar |
| Max. pressure Y | Not used; internally drained | Maximum flow | 300 l/min; subject to spool operating limits |
| Seals | NBR — mineral hydraulic oil HL / HM | Electrical connection | K1 — EN 175301-803 (DIN 43650); connector not supplied |
| Duty cycle | 100% ED | Voltage tolerance | ±10% |
| Protection | IP65 with correctly fitted, wired mating connector | Fluid temperature | −20 to +80 °C |
| Ambient temperature | −20 to +50 °C | Viscosity | 10–400 cSt; recommended 25 cSt |
| Cleanliness | ISO 4406:1999 class 20/18/15 | Availability | On order — lead time confirmed on enquiry |
Duplomatic DSP7-TB02/20N-CI/D24K1 NG16 directional control valve
The DSP7-TB02/20N-CI/D24K1 is a solenoid-actuated, pilot-operated hydraulic directional valve for industrial hydraulic systems, machine tools and power units. Its ISO 4401-07 mounting interface suits NG16 valve assemblies. The TB02 spool provides 4/2 spring return, open crossover operation with 1 solenoid and 24V DC supply.
Pilot and drain configuration CI
Internal pilot supply with backpressure valve in P. Internal drain to T. Internal pilot supply requires sufficient pressure in P. Above 210 bar, select a suitable Z/CZ reducer version or external piloting; do not apply the 350 bar main-stage rating to the pilot stage. The internal drain is connected to T; keep return-line pressure within 210 bar.
Selection and technical documentation
Check the selected spool symbol, pressure–flow curves, switching conditions and mounting dimensions in the catalogue before specifying a replacement. The 300 l/min value is the series maximum, not a guaranteed flow at every pressure or for every spool. The CAD file and rendered image represent the matching external construction; internal pilot/drain plugs and spool functions are defined by the ordering code and hydraulic diagram.
IMPEX CONNECT supplies hydraulic components to B2B customers. Send the required code and quantity for confirmed availability.