Product Description
Specifications
| Part number | QDE3-20/11N-D12K1 | Brand | Duplomatic MS |
| Valve type | Proportional pressure-compensated flow control valve | Mounting size | NG6 / ISO 6263-03 |
| Controlled flow QB | Up to 20 l/min | Maximum input flow QA, 3-port | 50 l/min |
| Maximum operating pressure | 250 bar | Minimum pressure drop A→B | 22 bar |
| Compensator spring setting | 8 bar | Configuration | 2- or 3-port, defined by subplate passages |
| Nominal coil voltage | 12 V DC | Nominal coil current | 1.88 A |
| Coil resistance at 20 °C | 4.4 Ω | PWM frequency | 100 Hz |
| Electrical connection | K1 — EN 175301-803 (ex DIN 43650) | Manual override | Integrated pin, standard (no knob) |
| Seal material | NBR (N), for mineral hydraulic oil | Catalogue mass | 1.4 kg |
| Duty cycle / valve protection | 100% / IP65 with suitable connector installed | Mounting interface | ISO 6263-03-03-*-97 |
| Ambient temperature | −20 to +60 °C | Fluid temperature | −20 to +80 °C |
| Viscosity range / recommended | 10–400 / 25 cSt | Fluid cleanliness | ISO 4406:1999, class 18/16/13 |
| Hysteresis | <6% of maximum controlled flow | Repeatability | <±1.5% of maximum controlled flow |
Duplomatic QDE3-20/11N-D12K1 proportional flow control valve
QDE3-20/11N-D12K1 is a direct operated, pressure-compensated proportional flow control valve for hydraulic branch-flow regulation and actuator speed control. The selected execution controls flow A→B up to 20 l/min, with a 12 V DC coil, K1 connection and NBR seals. The standard version has an integrated manual operating pin and no knob.
The same valve can operate with two or three ports, depending on the mounting plate passages. The T passage must not be connected to tank; the P passage is provided only for three-port operation. Maximum inlet flow QA in three-port operation is 50 l/min, distinct from controlled outlet flow QB of 20 l/min. Maximum working pressure is 250 bar and the minimum pressure drop A→B is 22 bar for this flow range.
Use a current-controlled supply or an appropriate external amplifier, such as EDC-141 / EDM-M141. Nominal coil current is 1.88 A and the specified PWM frequency is 100 Hz. Coil voltage alone is not a proportional command signal. Pressure compensation maintains the regulated flow against load-pressure changes within the catalogue operating conditions.
The zinc-nickel coated body mounts on ISO 6263-03-03-*-97. NBR seals are intended for HL/HM mineral hydraulic oils. The CAD image and DWG correspond to the standard, no-knob K1 construction. IMPEX CONNECT supports international B2B sourcing of QDE3-20/11N-D12K1 for industrial hydraulic systems. Confirm subplate porting, flow range and amplifier compatibility; delivery time is confirmed on request.