Skip to product information
Duplomatic QDE3 CK1 K1 - CAD 3D view

QDE3-30/11N-D12K1/CK1 - Duplomatic proportional flow control valve, 30 l/min, 12 V DC

€366,00
Excl. VAT
Send enquiry

Availability and delivery terms are confirmed by email on request.

Email this product enquiry directly


Product Description

Specifications

Part number QDE3-30/11N-D12K1/CK1 Brand Duplomatic MS
Valve type Proportional pressure-compensated flow control valve Mounting size NG6 / ISO 6263-03
Controlled flow QB Up to 30 l/min Maximum input flow QA, 3-port 40 l/min
Maximum operating pressure 250 bar Minimum pressure drop A→B 10 bar
Compensator spring setting 4 bar Configuration 2- or 3-port, defined by subplate passages
Nominal coil voltage 12 V DC Nominal coil current 1.88 A
Coil resistance at 20 °C 4.4 Ω PWM frequency 100 Hz
Electrical connection K1 — EN 175301-803 (ex DIN 43650) Manual override CK1 knob manual override
Seal material NBR (N), for mineral hydraulic oil Catalogue mass 1.4 kg
Duty cycle / valve protection 100% / IP65 with suitable connector installed Mounting interface ISO 6263-03-03-*-97
Ambient temperature −20 to +60 °C Fluid temperature −20 to +80 °C
Viscosity range / recommended 10–400 / 25 cSt Fluid cleanliness ISO 4406:1999, class 18/16/13
Hysteresis <6% of maximum controlled flow Repeatability <±1.5% of maximum controlled flow

Duplomatic QDE3-30/11N-D12K1/CK1 proportional flow control valve

QDE3-30/11N-D12K1/CK1 is a direct operated, pressure-compensated proportional flow control valve for hydraulic branch-flow regulation and actuator speed control. The selected execution controls flow A→B up to 30 l/min, with a 12 V DC coil, K1 connection and NBR seals. The /CK1 knob provides manual override.

The same valve can operate with two or three ports, depending on the mounting plate passages. The T passage must not be connected to tank; the P passage is provided only for three-port operation. Maximum inlet flow QA in three-port operation is 40 l/min, distinct from controlled outlet flow QB of 30 l/min. Maximum working pressure is 250 bar and the minimum pressure drop A→B is 10 bar for this flow range.

Use a current-controlled supply or an appropriate external amplifier, such as EDC-141 / EDM-M141. Nominal coil current is 1.88 A and the specified PWM frequency is 100 Hz. Coil voltage alone is not a proportional command signal. Pressure compensation maintains the regulated flow against load-pressure changes within the catalogue operating conditions.

The zinc-nickel coated body mounts on ISO 6263-03-03-*-97. NBR seals are intended for HL/HM mineral hydraulic oils. The CAD image and DWG correspond to the knob-equipped CK1 K1 construction. IMPEX CONNECT supports international B2B sourcing of QDE3-30/11N-D12K1/CK1 for industrial hydraulic systems. Confirm subplate porting, flow range and amplifier compatibility; delivery time is confirmed on request.

You may also like