Product Description
Specifications
| Part number | QDE5-80/11N-D24K1/CK | Brand | Duplomatic MS |
| Valve type | Proportional pressure-compensated flow control valve | Mounting size | NG10 / ISO 4401-05 |
| Controlled flow QB | Up to 80 l/min | Maximum input flow QA, 3-port | 90 l/min |
| Maximum operating pressure | 250 bar | Minimum pressure drop A→B | 22 bar |
| Compensator spring setting | 8 bar | Configuration | 2- or 3-port, defined by subplate passages |
| Nominal coil voltage | 24 V DC | Nominal coil current | 1.6 A |
| Coil resistance at 20 °C | 12 Ω | PWM frequency | 100 Hz |
| Electrical connection | K1 — EN 175301-803 (ex DIN 43650) | Manual override | CK knob manual override |
| Seal material | NBR (N), for mineral hydraulic oil | Catalogue mass | 4.4 kg |
| Duty cycle / valve protection | 100% / IP65 with suitable connector installed | Mounting interface | ISO 4401-05-04-0-05 |
| Ambient temperature | −20 to +60 °C | Fluid temperature | −20 to +80 °C |
| Viscosity range / recommended | 10–400 / 25 cSt | Fluid cleanliness | ISO 4406:1999, class 18/16/13 |
| Hysteresis | <6% of maximum controlled flow | Repeatability | <±2% of maximum controlled flow |
Duplomatic QDE5-80/11N-D24K1/CK proportional flow control valve
QDE5-80/11N-D24K1/CK is a direct operated, pressure-compensated proportional flow control valve for hydraulic branch-flow regulation and actuator speed control. The selected execution controls flow A→B up to 80 l/min, with a 24 V DC coil, K1 connection and NBR seals. The /CK knob provides manual override.
The same valve can operate with two or three ports, depending on the mounting plate passages. The T passage must not be connected to tank; the P passage is provided only for three-port operation. Maximum inlet flow QA in three-port operation is 90 l/min, distinct from controlled outlet flow QB of 80 l/min. Maximum working pressure is 250 bar and the minimum pressure drop A→B is 22 bar for this flow range.
Use a current-controlled supply or an appropriate external amplifier, such as EDC-131 / EDM-M131. Nominal coil current is 1.6 A and the specified PWM frequency is 100 Hz. Coil voltage alone is not a proportional command signal. Pressure compensation maintains the regulated flow against load-pressure changes within the catalogue operating conditions.
The zinc-nickel coated body mounts on ISO 4401-05-04-0-05. NBR seals are intended for HL/HM mineral hydraulic oils. The CAD image and DWG correspond to the knob-equipped CK K1 construction. IMPEX CONNECT supports international B2B sourcing of QDE5-80/11N-D24K1/CK for industrial hydraulic systems. Confirm subplate porting, flow range and amplifier compatibility; delivery time is confirmed on request.