Specifications

Part number QDE5-80/11N-D12K1/CK Brand Duplomatic MS
Valve type Proportional pressure-compensated flow control valve Mounting size NG10 / ISO 4401-05
Controlled flow QB Up to 80 l/min Maximum input flow QA, 3-port 90 l/min
Maximum operating pressure 250 bar Minimum pressure drop A→B 22 bar
Compensator spring setting 8 bar Configuration 2- or 3-port, defined by subplate passages
Nominal coil voltage 12 V DC Nominal coil current 2.8 A
Coil resistance at 20 °C 3 Ω PWM frequency 100 Hz
Electrical connection K1 — EN 175301-803 (ex DIN 43650) Manual override CK knob manual override
Seal material NBR (N), for mineral hydraulic oil Catalogue mass 4.4 kg
Duty cycle / valve protection 100% / IP65 with suitable connector installed Mounting interface ISO 4401-05-04-0-05
Ambient temperature −20 to +60 °C Fluid temperature −20 to +80 °C
Viscosity range / recommended 10–400 / 25 cSt Fluid cleanliness ISO 4406:1999, class 18/16/13
Hysteresis <6% of maximum controlled flow Repeatability <±2% of maximum controlled flow

Duplomatic QDE5-80/11N-D12K1/CK proportional flow control valve

QDE5-80/11N-D12K1/CK is a direct operated, pressure-compensated proportional flow control valve for hydraulic branch-flow regulation and actuator speed control. The selected execution controls flow A→B up to 80 l/min, with a 12 V DC coil, K1 connection and NBR seals. The /CK knob provides manual override.

The same valve can operate with two or three ports, depending on the mounting plate passages. The T passage must not be connected to tank; the P passage is provided only for three-port operation. Maximum inlet flow QA in three-port operation is 90 l/min, distinct from controlled outlet flow QB of 80 l/min. Maximum working pressure is 250 bar and the minimum pressure drop A→B is 22 bar for this flow range.

Use a current-controlled supply or an appropriate external amplifier, such as EDC-151 / EDM-M151. Nominal coil current is 2.8 A and the specified PWM frequency is 100 Hz. Coil voltage alone is not a proportional command signal. Pressure compensation maintains the regulated flow against load-pressure changes within the catalogue operating conditions.

The zinc-nickel coated body mounts on ISO 4401-05-04-0-05. NBR seals are intended for HL/HM mineral hydraulic oils. The CAD image and DWG correspond to the knob-equipped CK K1 construction. IMPEX CONNECT supports international B2B sourcing of QDE5-80/11N-D12K1/CK for industrial hydraulic systems. Confirm subplate porting, flow range and amplifier compatibility; delivery time is confirmed on request.